E-mail
ahtk777@163.com
-
Phone
18019831048
-
Address
No. 20 Renhe South Road, Tianchang City, Anhui Province
Anhui Tiankang (Group) Co., Ltd
ahtk777@163.com
18019831048
No. 20 Renhe South Road, Tianchang City, Anhui Province
Premium BPGVPVariable frequency cable,BPGVP2 frequency converter cable
The structure of a frequency conversion cable includes three main insulated wires and three neutral insulated wires. An inner winding layer, a copper strip layer, an outer winding layer, and an outer sheath layer are sequentially set outside the main insulated wires and neutral insulated wires to form a 3+3 core structure, which makes the cable have strong voltage impact resistance and can withstand pulse voltage during high-speed and frequent frequency conversion, providing good protection for frequency conversion electrical appliances
BPGVP |
Silicone rubber insulated PVC sheathed copper wire braided shielded frequency converter cable |
BPGVP2 |
Silicone rubber insulated PVC sheathed copper tape wrapped shielded frequency converter cable |
This specification specifies the rated voltageU0/UFor 0.6/1kVThe code and product identification method, structure, and testing requirements for high temperature resistant extruded silicone rubber insulated and sheathed control cables.
This specification is applicable to those with high temperature resistanceOr resistant to acid and alkali corrosionRequired rated voltageU0/UFor 0.6/1kVControl cables used in control, monitoring circuits, and protection circuits below.
000011 Normative reference documents
The provisions in the following documents become provisions of this specification by reference. Any referenced document marked with a date shall not be subject to any subsequent amendments (excluding errata) or revisions to this specification. However, parties to agreements based on this specification are encouraged to explore the possibility of using new versions of these documents. Any referenced document without a date shall apply to the new version of this specification.
GB/T 2900.10 Electrical Terminology - Cables
GB/T 2951-2008 General Test Methods for Insulation and Sheath Materials of Cables
GB/T 2952 Cable outer protective layer
GB/T 3048-2007 Test method for electrical performance of wires and cables
GB/T 3956 Conductors of Cables
GB/T6995Identification marks for wires and cables
GB/T 19666-2005 General rules for flame-retardant and fire-resistant wires and cables
JB/T 8137-1999 Cable Packaging Tray
JB/T 10696.7-2007 Test methods for mechanical and physicochemical properties of wires and cables Part 7: Tear resistance test
Premium BPGVPVariable frequency cable,BPGVP2 frequency converter cableSold to:Beijing, Shanghai, Tianjin, Chongqing Hebei, Shanxi, Shaanxi, Shandong, Henan, Liaoning, Jilin, Heilongjiang, Jiangsu Zhejiang, Anhui, Jiangxi, Fujian, Hubei, Hunan, Sichuan, Guizhou, Yunnan, Guangdong, Hainan, Gansu, Qinghai、Inner Mongolia, Xinjiang, Xizang, Guangxi, Ningxia
AHTKJTGFYXGSXSCXLW20180913