Overview

The American ECM exhaust particulate module pmCAN and automotive exhaust analyzer have changed the measurement of particulate matter in diesel and spark ignition engine exhaust. The system uses a spark plug sized particulate sensor, which can be simply screwed into the engine's exhaust pipe without the need for an air pump, compressed air, butanol, high power requirements, or bulky instruments, all of which are part of the cost of other particulate measurement systems.

Product Details

brand ECM price range 70000 to 100000
Detection Principle Other methods Instrument type online
Origin category Import Application field Environmental protection, energy, transportation, automobiles

American ECM exhaustAir particle module pmCANThe system has changed the measurement of particulate matter in the exhaust of diesel engines and spark ignition engines. It uses a spark plug sized particle sensor that can be screwed into the engine's exhaust pipe without the need for an air pump, compressed air, butanol, high power requirements, or bulky instruments, all of which are part of the cost of other particulate measurement systems.


Typical Applications
Diesel engine and spark ignition engine
Installation of engine exhaust outlet and exhaust pipe
Bench testing and use of testing vehicles


Measuring principle
The particles flowing between the electrodes of the particle sensor collide with the high-voltage electrode or ground electrode, causing the particles to be charged and then attracted to the electrode of opposite polarity, where they release the charge and generate an electric current. The current is measured by external electronic devices and is proportional to the density of particles flowing between the electrodes. A larger current means more particles.


Main parameters
Mass concentration: 0.05~100mg/m3
Quantity concentration: 0.24~480 M/cc (M/cc is mills/cc, for example: 0.24 M/cc is 240000 #/cc)
Accuracy: ± 10% * (accuracy can be improved by inputting an incremental table by the user)
Installation thread: 18mm × 1.5mm
Exhaust gas temperature: maximum 850 ℃
Module temperature resistance: -55~100 ℃
Cable temperature resistance: -55~220 ℃
Electronic module: dimensions 114mm × 120mm × 35mm, weight 540g, sealing grade IP27
Communication interface: CANopen, can set baud rate, can set Node ID
Power supply: 6~32 VDC, 0.14 A @ 12 V