EXOWater quality monitoring and measurement platform
●As an intelligent and field application water quality monitoring platform.EXO Having a wide range of water environment monitoring capabilitiesAbility to calmly respond to various water environment monitoring needs such as rivers, lakes, oceans, estuaries, and groundwater.
●EXO The series has two models EXO1 and EXO2It can meet different monitoring needs.
●Efficient power management, sturdy structure, stable sensor performance, and chemical free protectionStaining the system, causing EXO Can maintain intervals of up to 12 Provide accurate and reliable data on a weekly basis.
●with GPS The handheld device, intelligent probe, and cable free operation of the function and barometer make sampling simplerSingle quick.
●In EXO You will find numerous innovative designs on the platform that enable products to perform water quality measurements and data transmissionMore sturdy, durable, accurate, and convenient.
●Expand to meet current usage needs at a lower cost while still meeting future usage needsThe possibility of exhibition.
have YSI EXO Performance that can only be possessed

Technical Specifications:
sensor |
measurement range |
accuracy |
response time |
resolution |
barometer |
375 - 825 mmHg |
±1.5 mmHg |
- |
0.1 mmHg |
Blue-green algae phycocyanin |
0-100ug/L 0-100RFU |
Linear:R2>0.999,With RhodamineWTContinuous dilution related(0-100ug/mL) Detection limit:0.04ug/LPC |
T63<2s |
0.01ug/L; 0.01RFU |
chlorophyll |
0-400ug/L Chl 0-100RFU |
Linear:R2>0.999,With RhodamineWTContinuous dilution related(0-400ug/mL) Detection limit:0.09ug/LChl |
T63<2s |
0.01ug/L Chl; 0.01RFU |
conductivity |
0-200mS/cm |
0-100: Reading ±0.5%0.001mS/cm; 100-200:Reading ±1% |
T63<2s |
0.0001-0.01mS/cm |
depth(Non breathable) |
0-10m |
±0.04%FS(±0.004m) |
T63<2s |
0.001m (Depending on the measurement range) |
0-100m |
±0.04%FS(±0.004m) |
|||
0-250m |
±0.04%FS(±0.10m) |
|||
dissolved oxygen-optics |
0-500%air saturation |
0-200%: Reading ±1%or1%;200-500%:Reading ±5% |
T63<5s |
0.1%air saturation |
0-50mg/L |
0-20mg/L:±0.1mg/LOr the ± of the reading1%;20-50mg/L:Reading ±5% |
0.01mg/L |
||
fDOM |
0-300ppb(QSE) |
Linear:R2>0.999,300ppb QS(Quinine sulfate) The solution is continuously diluted. Detection limit:0.07ppb QSE |
T63<2s |
0.01ppb QSE |
ORP |
-999-999mV |
±20mV,Redox standard solution |
T63<5s |
0.1mV |
pH |
0-14 |
±0.1,Calibration temperature ±10℃ ±0.2, full temperature range |
T63<3s |
0.01 |
temperature |
-5—50℃ |
-5—35℃:±0.01℃ 35—50℃:±0.05℃ |
T63<1s |
0.001℃ |
turbidity |
0-4000FNU |
0-999FNU:0.3FNUOr the ± of the reading2%; 1000-4000FNU: Reading ±5% |
T63<2s |
0-999FNU:0.01FNU 1000-4000FNU:0.1FNU |