- Phone
-
Address
Room 702, Dingxin Building, Lane 3799, Chunshen Road, Minhang District, Shanghai
Shanghai Chengfeng Technology Co., Ltd
Room 702, Dingxin Building, Lane 3799, Chunshen Road, Minhang District, Shanghai
YSI 3100Universal conductivity meter:
●Using current driven technology, with a wide measurement range and built-in automatic range selection function
●Optional display of conductivity, specific conductivity, and salinity, temperature constant display
●Programmable linear temperature compensation coefficient0to4%, reference temperature can be compiled15to25℃
●Built in platinum plated conductive tube function
YSI3200Ultra pure water measuring conductivity meter:
●User selectable measurement parameters: conductivity, temperature, resistance, conductivity, salinity, resistivity, and total dissolved solids
●RRTResistance ratio technology (patent) provides measurement accuracy for ultrapure water
●New measuring tube with built-in temperature sensor
●Multi point calibration enables the same measuring tube to accurately cover a wide range of sample measurements
●From ultrapure water to3SThe water body has a built-in automatic range selection function
●Non volatile memory can be stored100Group readings and6Information on a conductive tube
●Linear and nonlinear temperature compensation
●Three temperature compensation options: input linear temperature compensation coefficient, preset nonlinear temperature compensation curve (two options), and self set nonlinear compensation curve (six options)
●Microprocessor control, large LCD display, tactile buttons, menu driven operating software, bidirectionalRS232interface
Technical Specifications
parameter |
YSI 3200Resistance ratio (patent) |
YSI 3100Current driven |
|||
conductance |
scope |
0-0.9999、0.950-9.999、 9.50-99.99、95.0-999.9、 950-9999MS; 9.50-99.99The95-999.9mS; 0.95-3.00S |
0-49.99MS/cm 0-499.9MS/cm 0-4999MS/cm 0-49.99mS/cm |
||
resolution |
0.0001、0.001、0.01、 0.1The1us; 0.01The0.1ms; 0.01S |
0.01、0.1The1MS/cm; 0.01mS |
|||
precision |
±0.30%、 ±0.20%、 ±0.10%、 ±0.10%、 ±0.30%、 ±1% |
±0.50% |
|||
resistance |
scope |
0-9.999Oh,0-99.99Oh, 0-999.9Oh? 0-9.999kOh,0-99.99kOh, 100.0-999.9kOh? 1.00-9.99MOh,10.0-29.9 MΩ |
none |
||
resolution |
0.001、0.01The0.1Oh? 0.001、0.01The0.1 kOh? 0.01The0.1 MΩ |
||||
precision |
±0.2%、 ±0.1%、 ±0.1%、 ±0.1%、 ±0.1%、 ±0.2%、 ±0.5%、 ±1% |
||||
salinity |
scope |
0-80ppt |
|||
resolution |
0.1ppt |
||||
precision |
±0.1ppt |
||||
temperature |
scope |
-5to+100℃ |
-5to+95℃ |
||
resolution |
0.01℃ |
0.1℃ |
|||
precision |
±0.1℃ |
±0.1℃+1 lsd |
|||
TDS |
scope |
0-19,999mg/L |
none |
||
resolution |
1mg/L |
||||
precision |
±0.50% |
||||
temperature compensation |
Linear and Nonlinear |
linear |
|||
Reference temperature |
0to100℃ |
15to25℃ |
|||
temperature coefficient |
0-10%, Nonlinear |
0-4% |
|||
Data storage |
100A measurement point |
none |
|||
Conductivity constant |
0.001to100/centimeter |
0.01,0.1,1,10/centimeter |
|||
Calibration of Conductors |
Gundam5point |
single point |
|||
output |
RS232 |
none |
|||
display |
Graphic LCD display |
LCD (Liquid Crystal Display) |
|||
power supply |
220V |
||||
certification |
UL,CSA,CE |
UL,CSA,CE |
|||