Welcome Customer !

Membership

Help

Changzhou Henglong Instrument Co., Ltd
Custom manufacturer

Main Products:

intelligent-mfg>Products
Product Categories

Changzhou Henglong Instrument Co., Ltd

  • E-mail

  • Phone

    18112315332

  • Address

    No. 72 Danyangmen South Road, Jintan, Changzhou

Contact Now

XLD-50 blood slurry machine

NegotiableUpdate on 04/21
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

A new multifunctional plasma dissolving machine has been independently developed to meet the needs of hospital blood banks. The machine adopts computer temperature control, can set the temperature arbitrarily, and has an accuracy greater than ± 1 ℃. It is equipped with automatic swing for simultaneous operation, which can automatically adjust the frequency, especially for melting plasma. Melting and swinging can be performed simultaneously. It is an ideal supporting tool for blood banks.

Product Details

XLD-50 blood slurry machineDetailed information:

Blood melting machineBrief Introduction

A new multifunctional plasma dissolving machine has been independently developed to meet the needs of hospital blood banks. The machine adopts computer temperature control, can set the temperature arbitrarily, and has an accuracy greater than ± 1 ℃. It is equipped with automatic swing for simultaneous operation, which can automatically adjust the frequency, especially for melting plasma. Melting and swinging can be performed simultaneously. It is an ideal supporting tool for blood banks.

Blood melting machineDetailed Introduction

The blood melting machine adopts digital display and computer temperature control. The temperature can be set arbitrarily according to different needs, with a water temperature difference of no more than ± 1 ℃. It is equipped with an automatic swing system that can automatically adjust the frequency, especially for melting plasma. Melting and swinging are carried out simultaneously, and it can be used after a few minutes of extraction. Reduced the number of procedures, saved time for rescuing patients, and facilitated medical workers. It is an ideal supporting tool for blood banks.
Blood melting machineMain technical parameters and characteristics:
(1) Temperature control 37 ℃± 0.5 ℃

(2) Accuracy of 0.5 ℃

(3) Power 1000W

(4) Thaw for 10 minutes

(5) 8-16 bags (200-400ml)
Blood melting machineAttention:
1. Normally set the water temperature, it can be turned on for a long time. When using it, turn on the swing switch, set the frequency, and it will automatically swing. After use, turn off the swing switch to save electricity and reduce mechanical wear.

2. Before use, be sure to add water to the water level line and avoid dry burning to protect the heating tube. As the startup time increases, the water in the water tank gradually evaporates. Please check the water level at any time (add water and replace it). Ensure that the machine is operating normally.

3. Temperature setting of blood plasma machine: Press the SET button to set or view the temperature setting point. Press the SET key once to start flashing the character, indicating that the instrument has entered the set state. Press the △ key to increase the set value, and press the △ or ▽ key to quickly change the data. Press the SET key again to return the instrument to normal working state. Once the temperature setting is complete, the heating indicator light will turn on.

4. Pre setting: Press the SET button for 3 seconds to enter the inner layer parameter setting state of the instrument. The parameter that appears and flashes is the advance amount that stops immediately. The advance amount parameter should be carefully adjusted to reduce temperature overshoot. When the instrument controls the heating output, it will cut off heating in advance. When the temperature drops below the advance amount, it will start heating again. The output (relay) will not work within the set value and advance amount range. This can reduce the number of relay actions and extend the service life of the relay. Example: If the set value is 50.0 ℃ and the advance amount is 0.5, the relay will release when the instrument control heats up to 49.5.0 ℃, and the relay will close again when the temperature drops to 50.0 ℃ -0.5 ℃=49.5 ℃. The larger the advance amount, the fewer times the relay will act, and if the advance amount is too large, it will reduce the control accuracy. After adjusting the advance parameter, press the SET button for 3 seconds to return the instrument to its working state. (Note: Pre setting is specifically set to prevent excessive temperature surge after heating stops, and generally does not require modification).

5. Error correction: When confirming that the value displayed on the instrument is not the correct measurement value, the displayed value can be corrected. Press the SET key for 3 seconds to enter the deep menu of the instrument panel. The parameter that appears and flashes is E00, which is the advance quantity. Press the SET key again to display the flashing parameter, which is the error correction parameter. Use the △ or ▽ keys to modify this parameter. The range of error correction is correct, and the instrument is corrected to be incorrect. Press the SET button to exit after the correction is complete for -9.9 ℃ to 9.9 ℃. The correction value of the instrument is 0.0 when it leaves the factory.