Transformer comprehensive characteristic testerMain features
• Support detection of CT and PT
Meet the requirements of regulations such as GB1207 and GB1208
Without the need for external equipment, all testing items can be completed on a single machine, and excitation and variable ratio polarity tests can be completed simultaneously in one test.
Equipped with a miniature fast printer, it can directly print test results on site
Easy to operate with intelligent prompts, making it easier for users to get started. .
Large screen LCD with graphical display interface
Automatically provide CT/PT (excitation) inflection point values according to regulations
Automatically provide 5% and 10% error curves
Can save 3000 sets of test data without losing it after power failure
Supports USB flash drive data transfer, which can be read through a standard PC and generate WORD reports
Small and lightweight ≤ 28Kg, very conducive to on-site testing
Transformer comprehensive characteristic testerThe main testing functions of the tester are:
| CT (protective, metrological) | PT |
| Voltage current characteristic (excitation characteristic) curve | Voltage current characteristic (excitation characteristic) curve |
| • Automatically provide inflection point values | • Automatically provide inflection point values |
| Automatically provide error curves of 5% and 10%, with measurable limit factor actual value (ALF) | • Ratio measurement |
| • Ratio measurement, polarity judgment | • Polarity judgment |
| • Differential measurement | • Differential measurement |
| • Phase (angle difference) measurement | • Phase (angle difference) measurement |
| • One flow test | • Communication voltage withstand test |
| • Communication voltage withstand test | • Secondary load test |
| • Secondary load test | Secondary winding direct resistance test |
| Secondary winding direct resistance test | • PT volt ampere voltage multiple adjustable (1.2-3.5) |
| • Measurable volt ampere characteristics of medium and low voltage transformers, zero sequence transformers | |
| • Measurable GIS, casing CT | |
| Comprehensive testing, completing excitation and variable polarity simultaneously in one test |
Main technical parameters of the tester:
| Project | Parameters | |
| working power supply | AC220V±10% 、50Hz | |
| Device output | 0-2500V 5KVA maximum setting value 20A | |
| High current output | 0~1000A | |
| Excitation accuracy | ≤ 0.5% (0.2% * reading+0.3% * range) | |
| Secondary winding resistance measurement | scope | 0.1~300Ω |
| precision | ≤ 1.0% (0.4% * reading+0.6% * range) | |
| Secondary actual Load measurement | scope | 5~500VA |
| precision | ≤ 0.5% (0.2% * reading+0.3% * range) ± 0.1VA | |
| phase measurement (Angle difference) | precision | 4min |
| resolution | 0.1min | |
| CT Variable ratio measurement | scope | ≤50000A/5A(10000A/1A) |
| precision | ≤ 0.5% (0.2% * reading+0.3% * range) | |
| PT Variable ratio measurement | scope | ≤500KV |
| precision | ≤ 0.5% (0.2% * reading+0.3% * range) | |
| working environment | Temperature: -10 ℃~40 ℃, humidity: ≤ 90%, altitude: ≤ 1000m | |
| size, weight | Dimensions: 450mm × 280mm × 340mm, Weight: ≤ 28Kg | |