-
E-mail
cqses@163.com
-
Phone
13509437005
-
Address
8-9, Building B, Nanping Building, Nanping East Road, Chongqing
Chongqing Sainz Instrument Co., Ltd
cqses@163.com
13509437005
8-9, Building B, Nanping Building, Nanping East Road, Chongqing
Thermo Scientific ™ TRACE ™ The 1310 gas chromatograph can help you improve productivity, accelerate response time, and reduce instrument holding costs. With its functional diversity and ultra-high GC and GC-MS performance, it is an ideal choice for large-scale production and QA/QC laboratories and research institutions. The system features a full touch screen design for instrument control, status monitoring, and method development on the instrument. With instant connection to the injection port and detector, you can replace modules, reconfigure different workflows, develop new methods, and save maintenance downtime in minutes.
Chongqing Thermo Fisher Scientific gas chromatographProduct Description
Switch between injection port and detector within minutes
No special training or tools required, switch between injection port and detector within two minutes
Significantly reduces maintenance downtime, and samples can be restarted within minutes
Immediately switch to a different workflow or method
increase productivity
Using robust injection port technology, analyzing dirty matrix samples requires almost no cleaning
With excellent detector sensitivity and micro volume technology, trace compounds can be analyzed with less injection volume and the smallest pre concentration results.
Adopting optional blowback technology can protect system components and reduce operating time and maintenance
The use of low heat capacity injection ports and detectors, as well as rapid furnace chamber technology, can shorten the cycle time of sample operation
Use a range of sample processing options to automate the entire workflow (from pipetting to injection)
Using Thermo Scientific ™ Dionex ™ Chromeleon ™ Chromatography Data System (CDS) software simplifies and accelerates data analysis
Reduce the cost of instrument ownership
Reconfigure the module system to meet different requirements, or share injection ports and detectors among several GCs
Adopting a tool free module for easy maintenance minimizes downtime
Allow the use of standard consumables to reduce operating costs
Energy saving through low heat capacity and fast start
Minimize sample and solvent consumption with trace sample functionality
Instant connection between injection port and detector options
Helium saving module
Split/No Split (SSL); Reverse blowing function is also optional
Programmed temperature injection port (PTV); Reverse blowing function can also be selected
Flame ionization detector (FID)
Thermal conductivity detector (TCD)
Electron Capture Detector (ECD)
Nitrogen phosphorus detector (NPD)
Flame photometric detector (FPD)
Gas sampling valve
Chongqing Thermo Fisher Scientific gas chromatographCompatibility of
Thermo Scientific ™ TriPlus ™ RSH automatic sampler
Thermo Scientific ™ TriPlus 300 Headspace Automatic Sample Injector
Thermo Scientific ™ TriPlus 100 LS liquid automatic sampler
Thermo Scientific ™ AI/AS 1310 Automatic Sample Injector
Thermo Scientific ™ ISQ ™ Single quadrupole GC-MS
Thermo Scientific ™ ITQ ™ GC ion trap MS system (can be deleted, this product has been discontinued by the factory)
Thermo Scientific TSQ ™ 8000 triple quadrupole GC-MS/MS
Thermo Scientific ™ TSuantum XLS ™ And Thermo Scientific ™ TSuantum XLS Ultra ™ Triple quadrupole GC-MS system
Thermo Scientific ™ DFS ™ High resolution GC-MS
Thermo Scientific ™ Delta V ™ Isotope ratio mass spectrometer
TRACE 1310 auxiliary furnace box
certification
International Electrotechnical Commission (IEC): 6100-1:2001-61010-2-010:2003-61010-2-081:2001+A1: (2003)
CAN/CSA C22.2 No. 61010-1 and UL 61010-1
European Standard (EN): 6100-1:2001-61010-2-010:04-61010-2-081:2002