Detection principle:
TR-750The total zinc analyzer and zinc ion detector are developed and designed according to the "Xylenol Orange spectrophotometric method" standard. Zinc can react with color reagents in a certain environment to form stable complexes, and then its absorbance is measured by spectrophotometry. After processing and calculation by a microcomputer system, the actual zinc content (mg/L) is directly determined. This instrument is widely used for the determination of surface water, surface water, wastewater, etc.
Product Features:
According to the "Xylenol Orange spectrophotometric method", the measurement is accurate and effective.
2. Adopting imported high brightness and long-life cold light source, with excellent optical performance and a light source lifespan of up to 100000 hours.
3. Large LCD screen with full Chinese display, direct data reading, simple and time-saving operation.
4. Integrated digestion and colorimetric analysis, no need to replace the tube, simple and fast measurement, and no safety hazards.
5. It can save 80 standard curves and 1800 measured values (date, time, parameters, test data).
6. Memory standard working curve, users can also calibrate the curve as needed.
7. One click factory reset, which can quickly recover in case of curve loss caused by misoperation.
8. It has a curve coverage interference function to prevent accidental operation of covering curves.
9. It has data storage function and data power-off protection function, making it convenient to query historical measurement data and prevent data loss.
10. Equipped with a USB interface, data can be transferred to the computer for permanent storage.
11. It has a printing function, which can immediately print the measured values or query historical records for printing.
Technical Specifications:
| Testing Standard | Xylenol Orange spectrophotometric method |
| Measurement range | 0-3ppm (segmented) |
| detection limit | 0.01ppm |
| Measurement accuracy | Error ≤± 5% |
| repetitiveness | ≤±5% |
| Optical stability | ≤± 0.001A/20 minutes (100000 hours lifespan) |
| Colorimetric method | Colorimetric tube for color comparison |
| power supply method | AC(220V±10%),50Hz |
| host size | 310mm*230mm*150mm |
| ambient temperature | 5~40℃ |
| ambient humidity | ≤ 85% non condensing |
| weight | <3kg |