TB125-3 Full Wind Through Pu Blower
Shanghai Liangjin Electromechanical Equipment Co., Ltd. mainly produces: all wind turbine, all wind CX turbine, all wind TB turbine, all wind HTB turbine, all wind PF turbine. The impeller of the turbine (also known as the turbine centrifugal fan) is covered with a mechanical shell, and the center of the impeller is the air inlet. When the medium pressure fan is working, the power equipment drives the impeller to rotate, drawing air in from the air inlet. During the rotation of the blades of a centrifugal fan, a dynamic force is applied to the gas, increasing its pressure and velocity. The gas is discharged from the exhaust port along the blade path under the action of centrifugal force.
It is mainly used in paper cutting machines, combustion air purifiers, cigarette filter forming machines, electroplating tank mixing, atomization drying machines, water treatment aeration, fish farming and breeding, silk printing machines, photographic plate making machines, injection molding machines, automatic feeding and drying machines, liquid filling machines, powder filling machines, welding equipment, film machinery, paper line conveying, cleaning of dry cleaning clothes, air dust removal, dry bottles, gas conveying, feeding, collection and other aspects, deep water aeration, various food machinery, packaging machinery, etc
Product Description:
1. High Performance: Reliable Quality Performance: Can be used at altitudes above 4000 meters and in deserts, resistant to high and low temperatures.
2. Low noise: High Rui low noise direct transmission is used, and there are built-in mufflers at both the inlet and outlet, which can reduce the noise during operation.
3. High reliability, almost maintenance free: Apart from the impeller, the high-pressure fan has no other moving parts, and the impeller is directly connected to the motor without gears or belts, making it more reliable and almost maintenance free.
4. Oil free and pollution-free: Since the impeller does not come into contact with other components, lubrication is not required.
5. Pressure stability: The mechanical precision is high, and the operating parts have undergone extremely precise balance design, testing, and calibration, resulting in extremely low vibration rates. Through practical applications in water treatment and electroplating, it has been proven that even stirring and water wave rolling height *.
Technical parameters of TB transparent fan for all wind blower:
Introduction to installation instructions:
1. The high-pressure fan should be placed in a relatively stable place, and the surrounding environment should be clean, dry, and well ventilated.
2. The rotation direction of the high-pressure fan impeller must be in the direction indicated by the arrow on the fan casing.
3. When the high-pressure vortex fan is working, the working pressure should not exceed 8kPa to avoid excessive heat generated by the fan and damage to the air pump caused by motor overcurrent.
4. Except for the two bearings of the motor rotor, there is no direct contact friction in other parts of the high-pressure fan. The installation method of bearings for this fan is mainly divided into two categories. *The bearing at the end of the class air pump is installed in the pump body between the motor base and the impeller, and this type of air pump does not need to be lubricated normally. The bearings on the second type of air pump end are installed in the middle of the pump cover, and the bearings on this type of air pump end should be regularly lubricated with grease (7018 high-speed grease). Once a month, for air pumps that work continuously in three shifts, the refueling frequency should be increased. The maintenance and upkeep of the bearings on the motor and fan end of this type of air pump shall be in accordance with the * type of air pump.
5. The filter screens and silencing devices at both ends of the high-pressure air pump should be cleaned in a timely manner according to the situation to avoid blockage and affect use.
6. The external connection of the inlet and outlet of the high-pressure air pump must be made using flexible hoses (such as rubber hoses, plastic spring hoses).
7. Replacement of bearings for high-pressure fans: The replacement of bearings must be carried out by personnel familiar with repair work. First loosen the screws on the pump cover, and then disassemble the parts one by one according to the order shown in the diagram. The disassembled parts should be cleaned, and then assembled in reverse order. When disassembling, do not forcefully pry the impeller, use a roller to remove it, and do not miss the adjusting gasket to avoid affecting the clearance that has been adjusted before leaving the factory.
8. The high-pressure vortex air pump strictly prohibits solids, liquids, and corrosive gases from entering the pump body.