STI100 gradient preparative liquid chromatography

NegotiableUpdate on 03/14
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
The STI series preparative liquid chromatography system adopts advanced technology from the United States, providing a fast and efficient large-scale separation system consisting of parallel pumps, UV visible detectors with advanced electronic circuits, 1200/mm concave grating optical path systems, and fully reverse controlled workstations. Mainly used in small laboratories for natural product separation, protein purification and identification, organic synthesis product separation and purification, fine chemical analysis, new drug compound screening, HPLC sample pretreatment.
Product Details


High pressure infusion pump

UV Visible Variable Wavelength Detector

Preparation of chromatographic column

Static Mixer

Chromatography workstation

7725i injection valve

Common toolkits

Computer+printer


(The configuration may vary slightly according to customer needs)



Liquid phase detection application

1438571021659160.jpg

High performance liquid chromatography HPLC detection scheme for doxycycline hydrochloride

-Sample processing procedure-

Accurately weigh an appropriate amount of doxycycline hydrochloride reference substance, add an appropriate amount of 0.01mol/L hydrochloric acid solution, dissolve by ultrasound, and dilute with 0.01mol/L hydrochloric acid solution to a solution containing approximately 1mg doxycycline hydrochloride per 1ml. Shake well, filter through a 0.45 µ m organic system filter membrane, accurately measure 20 µ L, inject into a liquid chromatograph, and record the chromatogram.

-Chromatographic conditions-

Chromatographic column: C18, 4.6 mm * 250 mm, particle size 5 µ m

Mobile phase: Acetonitrile: Acetate buffer solution=25:75

Wavelength: 280nm

Flow rate: 1.0mL/min


Instrument configuration:点击图标.pngPlease click to view the image details


1440577813503902.jpg

LC-10Tvp high-pressure constant current infusion pumpIt is a multifunctional constant current infusion pump with high flow accuracy, corrosion resistance, and high pressure resistance......

1440577845372569.jpg

SPD-10Tvp UV detectorA dual beam monochromatic system composed of imported deuterium lamps, photovoltaic cells, and 1200/mm concave gratings......

1440577865111026.jpg

8725i injection valveIt is a six way valve in which the sample is loaded through an embedded needle track in front of the valve......

1440577884811063.jpg

Vertex C18 ColumnFeaturing high surface coverage and complete tail sealing, it is suitable for chromatographic analysis in a wide range of pH values from 1.5 to 10.0......

1440577907110419.jpg

AP-01P oil-free vacuum pumpIt is a small vacuum pump with a lightweight and beautiful appearance, high efficiency, low noise, and adjustable pressure......

1440577925135421.jpg

VI2010 Chromatography WorkstationBreaking through the bottleneck of current domestic chromatography software only having serial port communication, truly realizing USB interface communication......



High pressure infusion pump:


Flow rate range: 0.01~100.00ml/min

Maximum pressure: 20Mpa,


Detector:


Flow pool volume3μL

Optical path 5mm

measuring range190-700nm

light sourceOptional deuterium lamp

Wavelength indication error±1nm

baseline noise≤5×10-5

baseline drift≤5×10-4Au/h

repeatability

Qualitative repeatability: ≤ 0.5%

Quantitative repeatability: ≤ 1.5%

signal output16 steps selected

AUTO ZEROFull-scale

controlkeyboard

RS232 communication

Remote control terminal (signal acquisition triggered)

Power supply power150W

weight25kg

External dimensions42cm*42cm*20cm



Liquid phase detection application

1438571021659160.jpg

High performance liquid chromatography HPLC detection scheme for doxycycline hydrochloride

-Sample processing procedure-

Accurately weigh an appropriate amount of doxycycline hydrochloride reference substance, add an appropriate amount of 0.01mol/L hydrochloric acid solution, dissolve by ultrasound, and dilute with 0.01mol/L hydrochloric acid solution to a solution containing approximately 1mg doxycycline hydrochloride per 1ml. Shake well, filter through a 0.45 µ m organic system filter membrane, accurately measure 20 µ L, inject into a liquid chromatograph, and record the chromatogram.

-Chromatographic conditions-

Chromatographic column: C18, 4.6 mm * 250 mm, particle size 5 µ m

Mobile phase: Acetonitrile: Acetate buffer solution=25:75

Wavelength: 280nm

Flow rate: 1.0mL/min


Instrument configuration:点击图标.pngPlease click to view the image details


1440577813503902.jpg

LC-10Tvp high-pressure constant current infusion pumpIt is a multifunctional constant current infusion pump with high flow accuracy, corrosion resistance, and high pressure resistance......

1440577845372569.jpg

SPD-10Tvp UV detectorA dual beam monochromatic system composed of imported deuterium lamps, photovoltaic cells, and 1200/mm concave gratings......

1440577865111026.jpg

8725i injection valveIt is a six way valve in which the sample is loaded through an embedded needle track in front of the valve......

1440577884811063.jpg

Vertex C18 ColumnFeaturing high surface coverage and complete tail sealing, it is suitable for chromatographic analysis in a wide range of pH values from 1.5 to 10.0......

1440577907110419.jpg

AP-01P oil-free vacuum pumpIt is a small vacuum pump with a lightweight and beautiful appearance, high efficiency, low noise, and adjustable pressure......

1440577925135421.jpg

VI2010 Chromatography WorkstationBreaking through the bottleneck of current domestic chromatography software only having serial port communication, truly realizing USB interface communication......