- Phone
-
Address
5th Floor, Building 3, Jinsheng Science and Technology Park, No. 611 Dongguan Road, Binjiang District, Hangzhou City, Zhejiang Province
Saizhi Technology (Hangzhou) Co., Ltd
5th Floor, Building 3, Jinsheng Science and Technology Park, No. 611 Dongguan Road, Binjiang District, Hangzhou City, Zhejiang Province
High pressure infusion pump
UV Visible Variable Wavelength Detector
Preparation of chromatographic column
Static Mixer
Chromatography workstation
7725i injection valve
Common toolkits
Computer+printer
(The configuration may vary slightly according to customer needs)

High performance liquid chromatography HPLC detection scheme for doxycycline hydrochloride
-Sample processing procedure-
Accurately weigh an appropriate amount of doxycycline hydrochloride reference substance, add an appropriate amount of 0.01mol/L hydrochloric acid solution, dissolve by ultrasound, and dilute with 0.01mol/L hydrochloric acid solution to a solution containing approximately 1mg doxycycline hydrochloride per 1ml. Shake well, filter through a 0.45 µ m organic system filter membrane, accurately measure 20 µ L, inject into a liquid chromatograph, and record the chromatogram.
-Chromatographic conditions-
Chromatographic column: C18, 4.6 mm * 250 mm, particle size 5 µ m
Mobile phase: Acetonitrile: Acetate buffer solution=25:75
Wavelength: 280nm
Flow rate: 1.0mL/min
Instrument configuration:
Please click to view the image details
|
LC-10Tvp high-pressure constant current infusion pumpIt is a multifunctional constant current infusion pump with high flow accuracy, corrosion resistance, and high pressure resistance...... |
|
SPD-10Tvp UV detectorA dual beam monochromatic system composed of imported deuterium lamps, photovoltaic cells, and 1200/mm concave gratings...... |
|
8725i injection valveIt is a six way valve in which the sample is loaded through an embedded needle track in front of the valve...... |
|
Vertex C18 ColumnFeaturing high surface coverage and complete tail sealing, it is suitable for chromatographic analysis in a wide range of pH values from 1.5 to 10.0...... |
|
AP-01P oil-free vacuum pumpIt is a small vacuum pump with a lightweight and beautiful appearance, high efficiency, low noise, and adjustable pressure...... |
|
VI2010 Chromatography WorkstationBreaking through the bottleneck of current domestic chromatography software only having serial port communication, truly realizing USB interface communication...... |
High pressure infusion pump:
Flow rate range: 0.01~100.00ml/min
Maximum pressure: 20Mpa,
Detector:
Flow pool volume3μL
Optical path 5mm
measuring range190-700nm
light sourceOptional deuterium lamp
Wavelength indication error±1nm
baseline noise≤5×10-5
baseline drift≤5×10-4Au/h
repeatability
Qualitative repeatability: ≤ 0.5%
Quantitative repeatability: ≤ 1.5%
signal output16 steps selected
AUTO ZEROFull-scale
controlkeyboard
RS232 communication
Remote control terminal (signal acquisition triggered)
Power supply power150W
weight25kg
External dimensions42cm*42cm*20cm

High performance liquid chromatography HPLC detection scheme for doxycycline hydrochloride
-Sample processing procedure-
Accurately weigh an appropriate amount of doxycycline hydrochloride reference substance, add an appropriate amount of 0.01mol/L hydrochloric acid solution, dissolve by ultrasound, and dilute with 0.01mol/L hydrochloric acid solution to a solution containing approximately 1mg doxycycline hydrochloride per 1ml. Shake well, filter through a 0.45 µ m organic system filter membrane, accurately measure 20 µ L, inject into a liquid chromatograph, and record the chromatogram.
-Chromatographic conditions-
Chromatographic column: C18, 4.6 mm * 250 mm, particle size 5 µ m
Mobile phase: Acetonitrile: Acetate buffer solution=25:75
Wavelength: 280nm
Flow rate: 1.0mL/min
Instrument configuration:
Please click to view the image details
|
LC-10Tvp high-pressure constant current infusion pumpIt is a multifunctional constant current infusion pump with high flow accuracy, corrosion resistance, and high pressure resistance...... |
|
SPD-10Tvp UV detectorA dual beam monochromatic system composed of imported deuterium lamps, photovoltaic cells, and 1200/mm concave gratings...... |
|
8725i injection valveIt is a six way valve in which the sample is loaded through an embedded needle track in front of the valve...... |
|
Vertex C18 ColumnFeaturing high surface coverage and complete tail sealing, it is suitable for chromatographic analysis in a wide range of pH values from 1.5 to 10.0...... |
|
AP-01P oil-free vacuum pumpIt is a small vacuum pump with a lightweight and beautiful appearance, high efficiency, low noise, and adjustable pressure...... |
|
VI2010 Chromatography WorkstationBreaking through the bottleneck of current domestic chromatography software only having serial port communication, truly realizing USB interface communication...... |