Phone
137-0612-2102
-
Address
3rd Floor, Block A, Building 2, Gaoxin North Science and Technology Park, Changzhou City, Jiangsu Province
Changzhou Ruixin Electronic Technology Co., Ltd
137-0612-2102
3rd Floor, Block A, Building 2, Gaoxin North Science and Technology Park, Changzhou City, Jiangsu Province
The three-phase rail smart meter can measure active and reactive energy in both forward and reverse directions, and can also measure the voltage, current, total active power, reactive power, power factor, and grid frequency of phases A, B, and C. It also has the function of recording maximum demand; Accumulate and store based on active and reactive power, as well as positive and negative total, peak, flat, and valley respectively (only high-end models have the function of multiple rate).
Programmable setting of two time zones per year, two time slot tables, 8 days of time slots, and four rates: peak, off peak, flat, and valley. The minimum interval between time slots is 15 minutes.
● It has data wheel display and data key display functions, and can query voltage, current, power factor, frequency, active power, reactive power, forward and reverse active energy, and forward and reverse reactive energy through the buttons on the panel. If no button is pressed within 8 seconds, the wheel display state will automatically switch, and the wheel display time is 4 seconds
● Optional display of maximum demand for U, I, P, Q, as well as peak, off peak, and valley total reactive energy in both directions.
● Reactive power pulse output, used for meter calibration and remote power collection. Passive optoelectronic isolation output port, pulse width: 80ms ± 20ms
The clock error is within 0.5S/day, and it has automatic switching functions for calendar, timing, and leap year.
● CommunicationagreementRS485 optoelectronic isolation communication interface, optional DL/T645-2007, MODBUS-RTU communication protocol.
Communication speed: 9600bps (default), 19200bps, 4800bps, 2400bps, 1200bps available.
project |
technical indicators |
||||
accuracy class |
Active power: Level 0.5, reactive power: Level 1.0 |
||||
rated voltage |
3×220V/380V |
||||
current specification |
1.5(6)A、5(20)A、10(40)A、20(80)A |
||||
Working Voltage |
Normal operating voltage range: 0.9~1.1Un Extreme working voltage range: 0.7~1.2Un |
||||
Reference frequency |
50Hz or 60Hz |
||||
starting current |
direct access |
0.004Ib |
|||
Connected via CT |
0.002In |
||||
power consumption |
Voltage line |
≤ 5VA/phase |
|||
Current line |
<4VA/phase |
||||
Voltage pulse output |
Pulse width: 80ms ± 20ms; optocoupler isolation, open collector output |
||||
digital communication |
RS485 interface, MODBUS-RTU, DT/T645-2007 protocol |
||||
clock error |
≤0.5s/d |
||||
temperature range |
Normal operating temperature: -10 ℃~+45 ℃; Extreme working temperature: -20 ℃ to+55 ℃; Storage temperature: -40 ℃~+70 ℃ |
||||
relative humidity |
≤ 95% (no condensation) |
||||
Mean time between failures (h) |
≥50000 |
||||
Dimensions (length x width x height) |
126×91×74(mm) |
||||


(This series of instruments adopts35mmStandard guide rail installation method)

(This instrument supports two wiring methods: direct connection and connection through a current transformer)