·Product Overview
This instrument can quickly and accurately measure multiple indicators in surface water, groundwater, urban sewage, and industrial wastewater, with direct concentration reading; Widely used in water treatment plants, domestic sewage treatment plants, purified water plants, beverage plants, food plants, environmental protection departments, industrial water use, epidemic prevention departments, urban water supply, environment, medical, chemical, pharmaceutical, aquaculture, biotechnology, fermentation processes, textile printing and dyeing, petrochemical, water treatment and other industries for rapid laboratory or field testing of water quality. It can also be matched with on-site rapid monitoring vehicles.
Instrument features:
※1Referring to the latest national standard testing methods, the photometric and electrode methods have been implemented using the latest software and hardware technologies(Independent testing)And titration method(Automatic calculation)Integration;
※2Integrated design of colorimetric system, digestion system, and protective cover, built-in type4The hole digestion system is equipped with an insulation layer attached to the upper end of the digestion hole to effectively ensure the digestion temperature. The instrument is equipped with a built-in air cooling device for digestionImprove heat dissipation speed to ensure detection accuracy;
※3The digestion system adopts a micro reflux rapid digestion method, which prevents organic matter from evaporating and samples from escaping through closed digestion. The integrated fully transparent protective cover ensures the safety of the digestion process and facilitates real-time monitoring of the digestion process;
※4Adopting a long service life10Ten thousand hours of cold light source, no need for light source cooling system, excellent stability;
※5Independent multi-channel optical path system, each channel is independently controlled and does not interfere with each other, effectively eliminating mechanical errors and improving detection accuracy;
※6Solid state detection system, no movable parts, strong seismic and moisture resistance performance;
※7The sample chamber is a square colorimetric cell to avoid errors caused by uneven walls of circular colorimetric tubes, resulting in higher measurement accuracy and color comparison The pool is suitable for multiple specifications of colorimetric dishes, meeting the needs of multiple parameter detection;
※8Built in photometric working curve and titration calculation program, no need to configure standard solution, can directly and quickly detect water samples;
※9Supports blank correction and multi-point correction of standard samples, which can automatically fit curves without manual calculation, making it convenient for users to expand detection items or correct system differences in test results
The line can be automatically saved and supports power-off retention;
※10Large screen Chinese menu display(7cunTFTcolorful touch screen)The reading mode includes absorbance values(A)Transmittance value(T), thick
Degree value(C);
※11Using specialized detection reagent kits to detect water samples greatly shortens reagent preparation time, increases detection efficiency, and simplifies operation;
※12Support one click storage, project name and reading information can be saved in real time for testing data, and each set of data corresponds to a unique testing date and time, making it easy to query; Recordable data50000Group, and can conduct data statistical analysis;
※13, possessing230Linear curve space, supporting manual modification, automatic correction or fitting, convenient for users to expand detection items;
※14Support one click printing, built-in printer, can print detection data in real time, and can also query and print historical data;
※15Equipped with data interface, professional online software is randomly provided, which can input sample name, testing project, testing institution and other information, and supports exportTXTperhapsEXCELFormat data report can be printed through an external printing system;
※16The portable chassis detection system and digestion system are integrated, and the size of the chassis complies with aviation and train carrying rules (can be placed under the seat and on the luggage rack), making it more convenient to carry around;
※17The portable chassis shell is equipped with waterproof strips, which have strong dust, water, corrosion, and impact resistance, and can effectively protect the equipment inside the box even in harsh environments.
※18Equipped with high-power lithium batteries as standard, high safety, capable of completing at least15Secondary dissolution process.
Technical indicators:
1Light source lifespan:≥100000h
2Stability:≤0.005A/h
3Detection system: multi-channel independent detection system
4Detection circuit: high-precision constant testing circuit
5Display mode: The Chinese menu on the large screen displays the absorbance value(A)Transmittance value(T)Concentration value(C)
6Measurement error:≤±5%perhaps±10%F.S
7Repetitive error:≤±3%
8Storage space: Detection data50000group
9Number of curves:230strip
10Printing method: Thermal line printing
11Dissolving temperature: room temperature~500℃
12Dissolving time:1~9999s
13Batch processing volume:4A water sample (optional)9、16One or more)
14Temperature control accuracy: <±1℃
15Uniformity of temperature field:<±1℃
16Communication interface: standardRS232(USBOptional)
17Power supply mode:220VCar power supply or lithium battery
Testing items:
|
Serial Number |
Parameter |
Measurement range |
Serial Number |
Parameter |
Measurement range |
|
1 |
Residual chlorine |
0.05~5.00mg/L |
34 |
magnesium-D |
2~200.0mg/L |
|
2 |
total chlorine |
0.05~5.00mg/L |
35 |
alkalinityD |
10.0~1000mg/L |
|
3 |
ozone |
0.05~2.50mg/L |
36 |
nitrate |
5.0~150.0mg/L |
|
4 |
Nitrite nitrogen |
0.01~0.40mg/L |
37 |
nitrite |
0.05~2.00mg/L |
|
5 |
Ammonia nitrogen |
0.05~10.0mg/L |
38 |
Orthophosphate |
0.1~1.0mg/L |
|
6 |
low turbidity |
0.5~60.0NTU |
39 |
chlorite |
0.05~2.0mg/L |
|
7 |
total phosphorus |
0.01~1.00mg/L |
40 |
sodium hypochlorite |
100~5000mg/L |
|
8 |
hexavalent chromium |
0.01~1.00mg/L |
41 |
sodium chromate |
0.01~1.00mg/L |
|
9 |
sulfide |
0.02~1.00mg/L |
42 |
peracetic acid |
0.0~10.0mg/L |
|
10 |
COD |
10~1000mg/L |
43 |
hydrogen peroxide |
1.0~100.0mg/L |
|
11 |
fluoride |
0.02~2.00mg/L |
44 |
hydrogen sulfide |
0.01~1.00mg/L |
|
12 |
dissolved oxygen |
0.1~10.0mg/L |
45 |
silica |
1.0~20.0mg/L |
|
13 |
manganese |
0.05~5.00mg/L |
46 |
urea |
0.5~10.0mg/L |
|
14 |
iron |
0.10~3.00mg/L |
47 |
Sulfite |
0.1~20.0mg/L |
|
15 |
calcium-D |
2~200mg/L |
48 |
detergent |
0.1~3.0mg/L |
|
16 |
chlorine dioxide |
0.10~3.00mg/L |
49 |
HYDRAZINE |
0.01~0.10mg/L |
|
17 |
nitrate nitrogen |
0.5~20.0mg/L |
50 |
FREE AMMONIA |
0.1~5.0mg/L |
|
18 |
high turbidity |
5~400NTU |
51 |
nickel |
0.05~0.5mg/L |
|
19 |
chroma |
5~200PCU |
52 |
tin |
0.01~0.50mg/L |
|
20 |
total chromium |
0.01~1.00mg/L |
53 |
acidity/phenolphthalein-D |
10.0~1000mg/L |
|
21 |
phosphate |
0.1~1.0mg/L |
54 |
carbonate-D |
10.0~1500mg/L |
|
22 |
sulfate |
5.0~250.0mg/L |
55 |
Bicarbonate-D |
10.0~1500mg/L |
|
23 |
CODmn-D |
0.50~8.00mg/L |
56 |
selenium |
0.10~1.00mg/L |
|
24 |
total hardness-D |
1.0~500.0mg/L |
57 |
temperature-J |
(-50~300)℃ |
|
25 |
formaldehyde |
0.05~1.50mg/L |
58 |
salinity-J |
(0.0~28)% |
|
26 |
Volatile phenol |
0.10~5.00mg/L |
59 |
potassium |
30.0~100mg/L |
|
27 |
PH-J |
2.0~14.0 |
60 |
cadmium |
0.10~5.0mg/L |
|
28 |
chloride-D |
20.0~500mg/L |
61 |
arsenic |
0.006~0.5mg/L |
|
29 |
cyanide |
0.03~1.00mg/L |
62 |
barium |
1.0~10.0mg/L |
|
30 |
aluminium |
0.01~0.50mg/L |
63 |
beryllium |
0.01~0.30mg/L |
|
31 |
copper |
0.05~1.00mg/L |
64 |
TDS-J |
0-9990ppm |
|
32 |
zinc |
0.05~3.00mg/L |
65 |
molybdenum |
0.01~0.30mg/L |
|
33 |
Free chlorine |
0.05~5.00mg/L |
66 |
silver |
0.05~1.00mg/L |
|
Note: Endings-JThe project is a pen ionization meter |
|||||