- Phone
-
Address
Room 706, Building 5, Xizi International Center, 898 Xiuwen Road, Minhang District, Shanghai (201199)
Shanghai Yifeng Instrument Equipment Co., Ltd
Room 706, Building 5, Xizi International Center, 898 Xiuwen Road, Minhang District, Shanghai (201199)
The smoke acid (HCl, HF, etc.) sampling system produced by PaulGothe company in Germany, the first half of the sampling system (particle sampling component) is used for sampling particles and acid mist inside or outside the flue, and the second half (gas sampling component) can be used for condensation absorption sampling of gaseous acids or other gaseous substances. The system mainly consists of: ① Joint sampling head, ② Particle sampling component, ③ Gas sampling component, ④ Drying tower, ⑤ ITES automatic constant velocity sampler, ⑥ Humidity measurement component (optional).


The ITES automatic constant velocity sampler (25.10) includes: an intelligent controller with built-in calibration holes; Sensor box, equipped with interfaces for connecting with pitot tubes and thermocouple sensors; High performance frequency controlled sampling pump with branch valve.
Joint sampling head
Generally, it consists of 2.07 (goose neck connecting tube with different diameter air inlet), 3.01 (front adapter, connecting suction tube and goose neck connecting tube), inner tube (ID 8mm), suction tube (OD 60mm G1/2), pitot tube, and thermocouple.
According to whether it is heated or cooled, it can be divided into three models: non heated (4.51), heated (4.62), and water-cooled (4.72). If the humidity is high and the temperature is high, it is recommended to heat the sampling head; If the temperature is very high, it is recommended to use a water-cooled sampling head.
Material options: T (titanium metal) and A (stainless steel). Available lengths are 500, 1000, 1500, 2000, 2500, and 3000mm.
Gas sampling component
Used for the collection of gaseous mercury, it consists of an absorption bottle (bubbler), an ice bath box, and a diaphragm pump (26.02-CP).
The absorption bottle model and size are as follows:
| 42.03 | Bubbler with frit D0 and check valve porous glass plate absorption bottle 250ml | 孔隙: 160~250μm E:Pan KS 19 A:Ball KS 19 | ![]() |
| 41.03 | Bubbler with frit D0 | I:Pan KS 19 E:Ball KS 19 | |
| 43.03 | Bubbler with frit D0 | I:Pan KS 19 E:smooth | |
| 42.03-I | Bubbler with Impinger and Check Valve Impact Absorption Bottle 250ml | I:Pan KS 19 E:Ball KS 19 | ![]() |
| 41.03-I | Bubbler with impinger | I:Pan KS 19 E:Ball KS 19 | |
| 43.03-I | Bubbler with impinger | I:Pan KS 19 E:smooth | |
| 45.01 | Carry box | Can hold a row of three absorption bottles | ![]() |
| 45.02 | Carry box | Can hold two rows of six absorption bottles | ![]() |
| 45.03 | Carry box | Can hold three rows of nine absorption bottles |
Note: Check valve is used to prevent liquid from flowing back into the sampling tube due to pressure drop when the pump is turned off at the end of sampling, and is used as the first absorption bottle.
Parameter
ITES automatic constant velocity sampler
Compliant with EN, ISO, and VDI standards
The transport box includes: an intelligent controller with built-in calibration holes, a sensor box, connected to pitot tubes and thermocouples, a rotary vane vacuum pump with good airtightness and corrosion resistance, and other connecting wires
Pressure difference: 0.01~10hPa (± 0.02 hPa)
Absolute pressure: 400~1300hPa (± 0.02 hPa output value)
Thermocouple temperature: 0~500 ℃ (± 0.4% output value)
Flow rate calibration hole: 0.5~4m3/h
Operating temperature: -10~60 ℃
Alarm output: 12V
Power supply: 220V
Weight (including pump): 18.9kg
Size: 350 x 280 x 250 mm
drying tower
Material: PVC
Diameter: 160mm
Height: 400mm
Weight: 3.4kg
Temperature: -10~60 ℃
Handheld components (optional)
Stainless steel pipe, used for fixing suction pipes with an outer diameter of 60mm
Length: Approximately 180mm
Weight: 2.3kg
Sound alarm
80dB, Used for exceeding the sampling parameter setting value or triggering an alarm at the end of sampling
Weight: 0.6kg