P270 High Performance Liquid Chromatography System

NegotiableUpdate on 03/19
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Product Introduction: Liquid chromatography technology is increasingly widely used for sample separation and purification in fields such as pharmaceuticals, chemical engineering, and biotechnology. Typical applications include purification of synthetic raw materials, preparation of standard substances, and purification of final products. The P270 preparation pump is controlled by a stepper motor, ensuring smooth infusion. It features a dual plunger structure with low pulsation and high performance indicators, complemented by UV series ultraviolet radiation
Product Details
P270Recommended configuration
Serial Number
product name
specifications
quantity
unit
1
P270 high-pressure infusion pump
Maximum flow rate of 99.99 ml/min
2
tower
2
UV230+UV Visible Detector (Preparation Type)
190-720nm, deuterium lamp+tungsten lamp
1
tower
3
Rehodyne 3725i-038 Manual Injection Valve
Standard configuration of 10ml quantitative ring (maximum configuration of 20ml quantitative ring)
1
branch
4
EC2000 Chromatographic Data Processing Workstation
Full Chinese interface, compliant with GLP requirements
1
cover
5
P270 Gradient System Startup Package
System Startup Package
1
cover
6
Preparation mixer
Static Mixer
1
tower
7
Semi prepared column
According to customer requirements, inner diameters of 50mm, 40mm, 30mm, 20mm, and 10mm are all acceptable
1
branch
8
fraction collector
According to customer requirements, choose between peak collection or time-based collection
1
tower
Note: The table shows the configuration of the P270 semi prepared gradient system, and there is also an optional P270 semi prepared isometric system.
performance index
P270
High pressure constant flow pump
Flow range
1.00mL/min-99.99 mL/min Set step size: 0.01 mL/min
Traffic accuracy
≤± 1.5% (30.00mL/min, 8.5MPa, water, room temperature)
Traffic stability
RSD≤1% 30.00mL/min, 8.5MPa, Water, at room temperature
maximum working pressure
30MPa (1.00mL/min-20.00mL/min)
20MPa (20.01mL/min-99.99mL/min)
Display pressure error
≤±3%
pressure pulsation
≤3.0%
power supply
AC 110V/220V,50Hz/60Hz
power consumption
260W
Dimensions (length x width x height)
420mm×280mm×175mm
UV230+
UV Visible Detector
wavelength range
190-720nm
Wavelength Repeatability
±0.1nm
Wavelength accuracy
±0.5nm
band width
6nm
response time
0.0-9.9s
linear range
≥1.5AU(5%)
baseline noise
≤±1.5×10-5AU
baseline drift
≤3×10-4AU/h
minimum detectable concentration
1.0×10-8G/mL (methanol solution of naphthalene)
CELL
Optical path length: 3mm, volume: 5 μ L
power supply
AC 110V/220V,50Hz/60Hz
power consumption
110W
External dimensions
(Length x Width x Height)
420mm×280mm×175mm
EC2000
Data processing workstation
Communication method
RS232
measuring range
-100mV~+2V
Signal resolution
2μV
Area resolution
0.1μV·s
Number of channels
Single channel or dual channel
repeatability
≤0.01%RSD