The OT318V coin operated exhaled gas alcohol content detector (hereinafter referred to as the alcohol detector) is an instrument specifically designed to test the alcohol content in human exhaled gas. The sensitive components of this machine adopt advanced electrochemical alcohol sensors, which have excellent sensitivity and repeatability; The testing process is reasonable, concise and convenient, with complete functions and multiple adaptive capabilities; Digital tube display, intuitive and clear; When the alcohol content in the exhaled gas of the test subject reaches the alarm threshold, the alcohol detector emits an audible and visual alarm indication.
Product Introduction
OT318The V coin operated exhaled gas alcohol content detector (hereinafter referred to as the alcohol detector) is an instrument specifically designed to test the alcohol content in human exhaled gas. The sensitive components of this machine adopt advanced electrochemical alcohol sensors, which have excellent sensitivity and repeatability; The testing process is reasonable, concise and convenient, with complete functions and multiple adaptive capabilities; Digital tube display, intuitive and clear; When the alcohol content in the exhaled gas of the test subject reaches the alarm threshold, the alcohol detector emits an audible and visual alarm indication.
Main functions
◆ Product Model:OT318V
◆ sensor type:Electrochemical alcohol sensor
◆ measurement range:0.000~4.000g/L(0.000~2.000mg/L、
0~440mg/100mL、0.000~0.400%BAC、
0.000~0.400g/100mL、0.000~2.000‰BAC)
◆ resolution:0.002g/L
◆ warm-up time:≤1min
◆ Drinking threshold:0.180g/L
◆ Critical value of drunkenness:0.500g/L
◆ Working environment conditions:Temperature:0℃~50℃
Humidity:≤ 95% RH without condensation
◆ Storage temperature:-20℃~60℃
◆ display mode:The test results are displayed on a four digit eight segment digital display;The testing steps and types of judgment results are indicated by red, green, and yellow light-emitting blocks.
◆ alarm method:Sound and light alarm
◆ Working Voltage:Adapter input:AC100V~AC240V,50/60HZ;
output:DC12V/1.5A
◆ testing unit:Six units are available for users to choose from: g/L, mg/L, mg/100mL,% BAC (g/100mL), and ‰ BAC
◆ indication error:±8%
◆ Single test coin quantity:0 to 15 pieces (can be set to 0)Coin testing)
◆ Applicable coin diameter:15mm~29mm
◆ Applicable coin thickness:1.8mm~3.0mm
◆ Coin tolerance:200 pieces
◆ Blowing tube box capacity:200 pieces (with an outer diameter of about 7mm)
◆ Sensor working life:two years
◆ host size:250mm×105mm×400mm
◆ host weight:about4kg
technical indicators