Phone
13501548758
-
Address
Unit 1404, Building 2, Xincheng International Apartment, No. 1100 Jiangnan Avenue South, Haizhu District, Guangzhou City
Guangzhou Sanyi Instrument Co., Ltd
13501548758
Unit 1404, Building 2, Xincheng International Apartment, No. 1100 Jiangnan Avenue South, Haizhu District, Guangzhou City


SidaCEDARTorque testerWDIS-IPS(05C / 5C / 20CL)
automatic/Management of semi-automatic tools
compareDISThe series is easier to use and has higher performance.
It can be used with personal computers orPLCIn conjunction with use,
To manage torque measurement to a higher degree.
Manual torque screwdriver/Wrench management, automatic and semi-automatic
Tool management, screw tightening/Loosening torque inspection.
Color displays can display various information.
The data output isUSBandRS232CStandard equipment.
follow50mN·m(0.05N·m)Go to500N·mof
A series of multiple measurement ranges.
Use optional wireless module to wirelessly transmit measurement data(*Please confirm with the supplier regarding the wireless module. )
pass through/The failure judgment is displayed in color for ease of understanding.
Technical parameters:
|
model |
WDIS-IPS05C |
WDIS-IPS5C |
WDIS-IPS20CL |
||
|
measuring range |
2.0-500mN.m |
0.020-5N.m |
0.20-20N.m |
||
|
kgf・cm/lbf・in/ mN・m |
kgf・cm/lbf・in/N・m |
kgf・cm/lbf・in/N・m |
|||
|
error |
±0.5% (499digitThe following ±3digit) |
||||
|
measurement direction |
CW-CCW (clockwise-anticlockwise) |
||||
|
Measurement mode |
Track, Peak(Peak Maintenance), Peak-Down (First peak retention), C (real-time output) |
||||
|
Zeroing time |
0.5-3Seconds (can be set within the instrument) |
||||
|
maximum/minimum/Average display |
Display and confirm the maximum, minimum, and average values of the stored measurement data |
||||
|
sampling period |
1000 data / 1second |
||||
|
Display clear to zero |
Clear the display at the set time 0.1second0.5~3.0Seconds (per second)0.5Seconds) |
||||
|
memory function |
up to800A data storage device |
||||
|
Success or failure judgment function |
Both the upper and lower limits can be set within the measurement range (however/The judgment of failure is in peak mode |
||||
|
power supply |
Communication adapter or4jointAAOn Battery |
||||
|
Attachment installation port |
□20 |
||||
|
External dimensions |
Body: 100 (w) × 105 (d) × 38 (h) (excluding probe) |
||||
|
Sensor Size |
φ44) H34.4 |
φ44) H34.4 |
φ49) H37.9 |
||
|
sensor |
|
|
|
||
|
OW-025 |
OW-10 |
OW-20 |
|||
|
accessory |
H20*W20*D20(5Surface probe sizeM2.6/ M2.6/3/4/5/6) |
H20*W20*D20(5Surface probe sizeM2.6/ M2.6/3/4/5/6) |
H5*20*D20,M4/M5/M6/M8 |
||
|
Specialized charger(AC100-240V 50/60Hz DC7.5V) |
|||||
|
Check the score sheet and calibration certificate |
|||||
|
data output |
RS 232 CandMini B USB ASCIIformat |
||||