Maglin Circular Magnetic Grid High Precision Angular Displacement Measurement System

NegotiableUpdate on 07/09
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

encoder

Product Details

encoder






● Non contact open magneto electric system

● Ultra small diameter multi reading head

● Super strong anti pollution ability

● The reading head is lightweight(<10g)

● Can eliminate seam errors

● The highest single cycle resolution can reach16position

● integrationSet-up LED

● Industrial standard digital and analog outputs are optional

● Special specification magnetic rings can be customized according to customer requirements

Inno servomaglinSeries high-precision circular magnetic grid angular displacementsensorIt is a non-contact open high-precision magnetic grid encoder system used for precise angular displacement feedback. The system uses a special magnetic ring as the scale of the system, even when larger than1mmAccurate measurement can still be achieved under the installation gap. The system adopts a multi reading head design for the diameter, which can effectively eliminate the eccentricity error of the system magnetic ring installation. The special magnetic sensing array design can effectively suppress the measurement error caused by the end face jumping caused by the vibration of the shaft. Meanwhile, the advanced signal microprocessor design enables the system to effectively reduce or eliminate seam errors in special magnetic rings. Especially in environments with large diameters and high pollution, such as high-precision servo turntables, aerospace simulations, and shell shooting aiming systems, where traditional circular gratings or circular magnetic gratings cannot solve the problem, this system can perfectly achieve accurate angular displacement measurement.

This system can output digital incremental square wave signals or analog sine and cosine signals that comply with industry standards for customers with different interface standards to choose from. Unique and concise design makesMaglinThe series of high-precision circular magnetic grid angular displacement measurement systems have more outstanding performance and better stability than traditional angular displacement encoders.

Built in multi reading head processorSet-up LEDThis series of circular magnetic grids can be installed more quickly and conveniently for customers, and can be achieved throughLEDThe color is used to detect and eliminate system faults in a timely manner(Green during normal operation, red when signal error occurs).

MaglinThe series of high-precision circular magnetic grid angular displacement measurement systems can be widely used in various unconventional customized measurement environments such as high-precision CNC digital processing systems, automation equipment, large-diameter servo turntables, theodolites, high-precision angle measuring instruments, torque sensors, seismic wave detectors, gyroscopes, transmission chain dynamic accuracy measuring instruments, screw dynamic accuracy measuring instruments, aerospace simulations, shell shooting aiming systems, military radar arrays, etc.

Installation size:


resolving power:

model

resolution

Interpolation coefficient

Maximum Running Speed

MagRA

491520

8192

400rpm

MagRB

245760

4096

800rpm

MagRC

122880

2048

2000rpm

MagRD

61440

1024

4000rpm

MagRE

30720

512

7000rpm

MagRF

15360

256

8000rpm

MagRG

7680

128

8000rpm

MagRH

3840

64

8000rpm

MagRI

1920

32

8000rpm

MagRJ

960

16

8000rpm

MagRK

480

8

8000rpm

MagRL

240

4

8000rpm

MagRM

120000

2000

2000rpm

MagRN

96000

1600

3000rpm

MagRO

60000

1000

4000rpm

MagRP

48000

800

4500rpm

MagRQ

30000

500

4500rpm

MagRR

24000

400

4500rpm

MagRS

19200

320

4500rpm

MagRT

12000

200

4500rpm

MagRU

9600

160

4500rpm

MagRV

6000

100

4500rpm

MagRW

4800

80

4500rpm

MagRS

2400

40

4500rpm



















Note: This table is applicable to
MaglinFor standard series magnetic rings and special size and resolution solutions, please call our company.


Installation method:

1、 First, fix the magnetic ring or ruler on the outer or inner circumference of the turntable with adhesive, and try to ensure that the ring plane is parallel to the turntable plane as much as possible;

2、 Keep the turntable rotating at a constant speed;

3、 Turn the reading headAPlace it above the magnetic ring detection surface and observe the multi head processor in real timeSet-up LEDThe color, when reading the headAWhen moving to the critical point where the red and green lights are on, turn the reading headAMove slightly towards the direction close to the magnetic ring detection surface, and then fix it to ensure Set-up LEDThe color is always green;

4、 Next, the reading headBPlace it on the reading headAThe distance between the magnetic ring detection surface and the diameter is equidistant, and a slight clockwise or counterclockwise displacement is made along the magnetic ring detection surface when the multi head processorSet-up LEDWhen the color changes from red to green, it indicates the first reading headAWith the second reading headBThe phase has been calibrated, and now the second reading head will be usedBThe position is basically fixed.

5、 Move the reading head that has already been calibrated for radial phase along the radius direction towards the magnetic ring detection surface, and follow the recommended distance from the magnetic ring detection surface according to the installation dimensions0.8mm)Fixed to ensure optimal measurement accuracy;

6、 Lock the fixing screws of the reading head with thread locking adhesive to prevent loosening caused by vibration, or use epoxy adhesive (permanently fixed at once) to drip onto the fixing parts of the reading head and screw to ensure reliable radial phase and optimal distance from the magnetic ring detection surface. At the same time, adjust the lead output of each reading head and fix it with corresponding plastic clips.

Operating environment and electrical parameters:

Power Supply: 5V ±5%(24VOptional)

power waste: <30mA(No load)

Temperature: -10-80linear measure

Humidity: 10-90%relative humidity

Protection level:IP67(Reading head)

Acceleration: run20G

Cable: 4.9mmStrengthen shielding and wrap ultra flexible cables, various lengths can be customized according to specific customer requirements



Maglin Circular Magnetic Grid High Precision Angular Displacement Measurement System. pdf