Lai Heng L-806 Fully Automatic Solid Liquid Extraction InstrumentThe Soxhlet high-efficiency hot extraction system is widely used in various solid-liquid extraction experiments, such as analyzing the fat content in food, beverages, and structures; Analyze soluble substances in textiles, pulp, packaging materials, soil, etc.
The test results comply with the national standard (GB5512-85)
★ Compliant with AOAC method
★ Fully automatic program control without supervision
★ Manually operate any step according to the experimental requirements
★ 6 samples can be operated continuously for 24 hours
★ Hot extraction steps according to AOAC standard method
Lai Heng L-806 Fully Automatic Solid Liquid ExtractionThe instrument adopts a four step hot extraction technique: hot extraction - rinsing - solvent recovery - drying. This product is designed to be intuitive, flexible, and convenient to operate. The instrument design comprehensively considers various control requirements in the experiment, can run according to pre-set programs, can store 99 self written programs, and can also be manually operated at any time, fully adapting to the control requirements of experimental personnel.
Step 1: Extraction
Hot extraction: Heat the container containing the sample and solvent for hot extraction.
Step 2: Rinse
There are two methods to choose from: continuous rinsing and intermittent rinsing. Rinse the sample with distilled condensed solvent, and the rinsing time, solvent amount, and intermittent rinsing interval can be set arbitrarily.
Step 3: Solvent Recovery
The solvent vapor is condensed and recovered in the solvent chamber.
Step 4: Drying
Evaporate the organic solvent in the sample cup, pre dry the extraction results, and automatically stop heating after the drying time is complete.
Technical parameters of Laiheng L-806 fully automatic solid-liquid extractor:
Control method: Microcomputer program controls LED display
Repeatability: relative error ± 1% or better
Solvent recovery rate: ≥ 85%
Measurement time: reduced by 20-80% compared to traditional methods
Temperature control range: Room temperature+5 ℃~280 ℃
Temperature control accuracy: ± 1 ℃
Sample cup capacity: 90ml
Whole machine power: < 1800W
Power supply voltage: 220V/50HZ
Net weight: 45Kg
Instrument dimensions: 660 (faucet switch+40) * 350 (handle+190) * 850mm
Typical User List:
Yunnan Zhaotong Normal College
Suzhou Medical College
Xinzhou Grain Quality Monitoring Center
Jinzhong Grain and Oil Testing Center
Jincheng Grain and Oil Testing and Inspection Center of Jincheng Grain Bureau
Lvliang Grain and Oil Science Research Institute
School of Life Sciences, Southwest University of Science and Technology
Nanyang Normal University
Songyuan Grain and Oil Hygiene Inspection and Monitoring Station
Fushong County Grain Bureau Grain and Oil Quality and Health Inspection Monitoring Station
Siping Grain and Oil Hygiene Inspection and Monitoring Station