Phone
137-0612-2102
-
Address
3rd Floor, Block A, Building 2, Gaoxin North Science and Technology Park, Changzhou City, Jiangsu Province
Changzhou Ruixin Electronic Technology Co., Ltd
137-0612-2102
3rd Floor, Block A, Building 2, Gaoxin North Science and Technology Park, Changzhou City, Jiangsu Province
Both water and gas meters use photoelectric direct reading absolute coding method, which automatically remembers the position of the code wheel without initialization; Directly reading the counter code disk reading of the meter, which is the "reading window value", without the secondary measurement process of cumulative pulses and converted values, and without cumulative errors. Implemented direct reading of data from the meter wheel, ensuring complete consistency between meter measurement data and backend data.
The electronic parts inside the meter do not have any mechanical contact with devices such as the digital dial, which does not affect the measurement accuracy and does not change the display mode of mechanical measurement.
Adopting advanced encoding technology and position recognition algorithms, it ensures accurate recognition of the number displayed on the character wheel code disc, completely solving the problem of accurate recognition of carry caused by mechanical asynchrony when multiple character wheel code discs rotate simultaneously.
Adopting a reflective photoelectric signal acquisition method, the 4-digit character wheel code wheel digits are directly recognized, eliminating the phenomenon of reading confusion caused by the use of software discrimination for the thousand digit character wheel.
Adopting M-BUS bus technology and low-power design, there is no need to distinguish positive and negative polarities, no need for external power supply, and a dedicated collector provides instant power supply for reading.
RS485 communication interface can be selected, with optoelectronic isolation design, and the collector can be shared with smart meters. It requires a switch power supply for power supply.
All measuring instruments have a unique ID number when they leave the factory, and complete production, commissioning, use, and maintenance records are established.
Fully sealed design, good waterproof performance, can work normally when immersed in water.
Not susceptible to external strong magnetic attacks, with extremely high anti-interference performance; Effectively solve the problems of water meter inversion and water hammer.
| 1. Usage environment: | Working water pressure ≤ 1MPa, working water temperature 0.1 ℃~30 ℃, maximum allowable pressure loss ≤ 0.063MPa |
| 2. Accuracy level: | Measurement accuracy level 2, maximum allowable error: high zone ± 2%, low zone ± 5% |
| 3. Nominal caliber: | DN15~20mm |
| 4. Traffic parameters: | Common flow rate of 2.5~4.0m3/h, common flow rate/minimum flow rate=125, boundary flow rate/minimum flow rate=1.6 |
| 5. Reading range: | 0.0001~9999.9999 |
| 6. Electrical parameters: | Working environment: temperature 0 ℃~60 ℃, humidity ≤ 95% RH |
| Current usage: working ≤ 25mA, standby ≤ 1.1mA | |
| Header recognition response time: 400ms | |
| Collection method: Adopting reflective photoelectric sensing technology, directly reading 4-digit character wheel data | |
| Interface type: RS-485, M-BUS | |
| Wiring method: RS-485 adopts a 4-wire system with a voltage of DC12V; M-BUS adopts a 2-wire system with a voltage of DC32V | |
| Communication speed: 1200/2400bps | |
| Transmission distance: greater than 1000m |