- Phone
-
Address
Room 322, Building A, Lane 168, Chengnan Road, Huinan Town, Pudong New Area, Shanghai
Shanghai Hengze Technology Co., Ltd
Room 322, Building A, Lane 168, Chengnan Road, Huinan Town, Pudong New Area, Shanghai
Product Information
LUMiReader PSA can instantly measure samples and obtain extinction spectra,. Each LUMiReader contains a focusing device and temperature control element, each of which can operate independently, ensuring maximum flexibility and accuracy of the instrument.
In addition, specially designedThe PSA module has also opened up new horizons for high-resolution particle measurement, allowing you to measure the velocity distribution of dispersed particles. Therefore, you do not need to specifically know the viscosity or density of the sample.
Our proprietary design ensures that light passes through the entire sample with minimal intensity variation or bending, ensuring maximum sensitivity and reproducibility. Each optical detector hasMore than 9000 highly sensitive micro resolution sensors can even accurately detect small local changes throughout the entire sample in real-time.
This design solves the problem of time-consuming and inaccurate scanning of samples, allowing you to capture any subtle changes that occur during the dispersion process.
LUMiReader also utilizes patent tilt technology based on joint boycott. The recognized principle is to increase the separation rate by 1 g by tilting the sample in a normal upright position without the need for external force. The acceleration size (up to 10 times) depends on geometric factors such as tilt angle, vial size, and sample type.
Analyze specifically based on viscosity, temperature, and concentration. With the advantage of observing the entire sample from top to bottom simultaneously, you can simultaneously observe and understand different stability levels/Unstable behavior, such as stratification, settling, coagulation, and flocculation of products at their original concentration.
LUMiReader undergoes certification and factory pre calibration before entering the market.
Multi-wavelength
LUMiReader PSA has achieved for the first time volume detection of suspensions and emulsions based on particle size distribution (ISO 13317), without the need to know the refractive index or assume that the particle shape is spherical and uniform.
This broadens a new perspective for the characterization of industrial products where the above parameters are not available or applicable. Analyzer applicationThe STEP technology protected by LUM patents is a unique and innovative measurement method that utilizes multiple wavelengths to obtain spatial-temporal extinction spectra.
Considering that apart fromISO TR 13097 provides direct stability results for fluid particle density, separation speed, and particle size (ISO 13317). The new LUMiReader PSA is a simple and comprehensive instrument for understanding complex industrial products.
PCA
In addition, the uniquely designedThe PSA module can test the distribution speed of particle separation. You don't need to know any material constants, such as viscosity or density.
|
Velocity distribution |
|
Intensity weighted particle size distribution QInt (x), qInt (x) |
|
Volume weighted particle size distribution Q3 (x), q3 (x) |
|
-Direct measurement without calibration/understanding of material properties |
|
-Quantitative information of particle size distribution |
|
-Quantitative information on particle size and volume fraction for each class |
|
-Always Effective - Quick Information on Quality Control |
|
|
|
-Convert into quality or quantity distribution |
|
-Qualitative information about particle size and dispersion |
|
|
|
|
Application field
Grinding material,asphalt,carbon black,ceramics,原油,fine chemicals,food,oil and gas,ink,gasoline,pharmaceutical,polymer materials,sludge,mud,And more materials.
advantage
Direct, rapid, and objective characterization of any separation phenomenon
Analysis under Original Conditions
Under normal gravity, patented accelerated phase separation
No moving parts
Endless monitoring of behavior of storing information samples for a long time
Suspension and emulsion used for concentration and dilution
Different types and customizable applications
Easy to operate, comprehensive information
High end analyzers prepared for high-quality control, process monitoring, and research and development
Product Specifications
|
Accelerated phase separation |
|
Up to 10 times the gravity |
|
Sensitivity testing |
|
Up to 250 times |
|
particle size distribution |
|
500 nm to 300 μms |
|
Observation time |
|
0.5 seconds to infinite duration |
|
meet the standard |
|
ISO/TR 13097; ISO 13317; ASTM D7827, CFR 21 Part 11 |
|
sample size |
|
1 piece |
|
sample capacity |
|
0.5 ml to 4.0 ml |
|
concentration |
|
0.00015% to 75% |
|
density |
|
Up to 22 g/cm ³ |
|
particle size |
|
200 nm 到 2000 μm |
|
light source |
|
Multi-wavelength |
|
temperature control |
|
The operating environment temperature is 3 ℃ higher, with a maximum set temperature of 60 ℃, ± 1K |
|
angle |
|
Vertical to 5 °, 10 °, 15 °, 20 °, 25 °, 30 ° |
|
sample tube |
|
Different optical path materials |
|
Size (WxHxD) |
|
29 x 24 x 44 cm |
|
weight |
|
11 kg |
|
power supply |
|
24V, Adapter (100V to 240V) |