Industrial Siemens industrial computers have high flexibility and user-friendly interfaces in debugging, operation, service, and maintenance, thereby reducing user costs The new SIMATIC IPC227D Nanobox PC, which adopts the first generation InAtom technology optimized for energy consumption, was launched in the Chinese market on October 1, 2011. $n $n Application Fields $n $n The new SIMATIC IPC277D Nanobox PC can be used to perform simple control, visualization, data acquisition, and communication tasks directly on the machine: $n $n can perform simple measurement and control, for example, by applying
| Brand: Siemens Industrial Control | Model: IPC-227D | Equipment type: Industrial control computer |
| Item number: KAM0902582 | Listing time: 2015 | Source category: Ordering |
| Type: Desktop | OEM: OEM available | Weight: 2KG |
| Does it support proxy joining? Yes | Shipping time: 1-3 days | After sales type: National warranty |
| Warranty: One year | Invoice: Provided | Packing list: accessory box |
| Cross border source: No | | |
Industrial Siemens industrial computerProduct description
The new SIMATIC IPC227D Nanobox PC, which adopts the first generation InAtom technology optimized for energy consumption, was launched in the Chinese market on October 1, 2011.
Application field
The new SIMATIC IPC277D Nanobox PC can be used to perform simple control, visualization, data acquisition, and communication tasks directly on the machine:
Easy measurement and control can be achieved, for example, through SIMATIC WinAC RTX and RTX-F soft PLCs suitable for fail safe applications
Featuring a simple human-machine interface, such as through SIMATIC WinCC RT Advanced
Capable of performing communication and data collection tasks, and can be used as an industrial gateway
SIMATIC IPC227D has obtained CE certification, allowing its use in industrial, household, and commercial sectors, and can therefore be deployed in industrial and building automation systems or public facilities. Its basic model has a capacity of only about 1 liter and can be integrated in situations with limited space.
Industrial Siemens industrial computeruse:
1. During the use of industrial control computers, please do not disassemble them randomly. If any malfunctions occur, please refer to the common faults and troubleshooting methods of industrial control computers first. When the industrial computer is in normal use, please do not move it to avoid damaging the hard drive due to vibration. The monitor is prone to scratches. Please do not use regular tissues, cloth products, etc. to wipe the screen, and do not touch the screen with sharp objects such as fingers or pens. Instead, use monitor wiping items to handle it.
2. To ensure good heat dissipation of the industrial computer, please regularly clean the dust sponge of the industrial computer. To ensure the reliable operation of the industrial computer, please regularly perform disk cleaning and disk fragmentation on the hard drive. To prevent data loss due to unexpected malfunctions, important data in the industrial computer should be backed up regularly. If the industrial personal computer you use needs to be connected to the Internet or LAN, in order to ensure the reliable operation of the industrial personal computer, please install anti-virus software and keep it updated regularly to prevent slow response and control errors caused by virus attacks.
3. Please use a licensed operating system and related application software. If you need to install other application software, please read the software manual you want to install, confirm whether the software is compatible with the operating system of the industrial computer, and confirm whether your industrial computer hardware configuration meets the requirements of the software for industrial computer hardware. The editor suggests that you use a dedicated industrial computer and assign someone to manage it.
4. After the industrial control machine is turned on again, please wait for at least 8 seconds. To ensure the reliable operation of the industrial computer, please do not change the BIOS settings of the motherboard at will. Do not plug or unplug the board with electricity to avoid static damage. When the industrial control machine experiences a power outage due to non-human factors, in order to ensure the normal and reliable operation of the industrial control function, the editor strongly recommends that you immediately disconnect the power supply of the industrial control computer, confirm the stability of the power grid, and then turn on the power to ensure the stable operation of the industrial control computer.

SIMATIC IPC277D(Nanopanel computer)19 "touch screenTFT,front
USB; 2x 10/100/1000 MBit/s Ethernet RJ45; 3 U'sSB2.0 (high current) ): 1x serial (COM 1); CF card slot; 24V DC power supply


| display screenSpecifications | 19 'TFT touch |
| Screen fordiagonal | 19 in |
| divideresolution(Pixel) | |
| ● Horizontal image resolution | 1366 Pixel |
| ● Vertical image resolution | 768 Pixel |
| backlight | |
| ●MTBF 背景照明(Temperature is 25 ° C)C time) |  |

| loseEnter the device |
| ● Front end mouse | No |
| keyboardfont | |
| ● function key | no |
| ● Alphanumeric keyboard | no |
| touchscreen | |
| ● Touch screen specificationsgrid |  |

| Anpretendform | Panel stylePC, built-in equipment |
| centralizedinstall | yesof |
| Distributed installation | no |
| canInstalled vertically(Vertical format) | yesof |
| YunMaximum installation angle allowed+/- |  |

| electricityVoltage type of the source | 24V DC |
| Power supply andVoltage open circuit jumper | |
| ●power outage/Power outage crossover time |  |



| Optical driver | can pass through USB As an external driver |
| drivedevice/Specification of storage medium, hard drive | CF or SSD |
| SSD |  |

| LordsaveStorage container | 1 GB to 2 GB |
| LordStorage capacity of the memory, maximum value |  |

|   guaranteeRange of retained data(including time, counter, marker), maximum value |

| insertgroove |
| ● SmalltypeNumber of flash memory slots |  |

| USB interface | yes |
| keyplate/Mouse interface | USB/USB |
| skewerLine interface | COM1 (RS 232) |
| industryEthernet | |
| Industrial Ethernet connection口 | 2x Fast Ethernet |
| —100 Mbit/s | yesof |
| — 1000 Mbit/s |  |

| Monitoring function |
| ● Temperature monitoring device | yesof |
| ● Monitoring dogs | yesof |

6AV7881-5A.0.-. ..0
riseStart page2/4
2019/8/28
guaranteeLeave the right to change © Copyright Siemens



| ● FormstateLED | No |
| ● fan |  |

| IP(front) | IP65 |
| IP(back side) |  |

| license | CE,cULus(508) |
| CE mark | yesof |
| cULus | yesof |
| shipShip construction permit | |
| ● GermanyLloyd's Register of Shipping(GL) | Yes;7', 9', 12' |
| ● United States Shipbuilding Inspection Service(ABS) | Yes;7', 9', 12' |
| ● Bureau Veritas International Inspection Group(BV) | Yes;7', 9', 12' |
| ● Norwegian Classification Society(DNV) | Yes;7', 9', 12' |
| ● UKLloyd's Register of Shipping(LRS) |  |

| Running environmenttemperature |
| ● OperationThe ambient temperature in |  |

| operationsystem | Windows 7 Ultimate(Multilingual) 32-bit/64 bit |
| Pre installed operating system | yes |
| Pre installed operating system | |
| ●Windows XP Professional | yesof |
| ●Windows 7 |  |



| Operation unit(Wide)x high), Unit mm | 483 mm x 337 mm |
| ● Operating unit width | 483 mm |
| ● Operating unit height | 337 mm |
| collectionChineseInstallation dimensions during installation(Wide)x high x deep), Unitmm | |
| ● width | 464 mm |
| ● height | 318 mm |
| ● depth | 73 mm |
| AnInstall cross-section/Device depth (width)x high x deep) |  |

Centralized installation formin the formulaPC panel, approximately

6AV7881-5A.0.-. ..0
riseStart page3/4
2019/8/28
guaranteeLeave the right to change © Copyright Siemens
upOne modification:
2019/8/24

6AV7881-5A.0.-. ..0
riseStart page4/4
2019/8/28