-
E-mail
stchenxin@163.com
-
Phone
13902218596
-
Address
Room 114, No. 13 Hengshan Road, Longhu District, Shantou City
Shantou Keyi Instrument Equipment Co., Ltd
stchenxin@163.com
13902218596
Room 114, No. 13 Hengshan Road, Longhu District, Shantou City
HT300A high-efficiency gas-phase liquid automatic samplerFeatures:
★ Elegant and generous rotary injection method, does not occupy the injection port, and takes into account manual injection;
The injection needle uses four different solvents or sample cleaning to minimize sample cross contamination to the greatest extent possible;
For certain models of gas phase, two injection ports can be used simultaneously, with the function of a dual tower automatic sampler;
★ Internal standard injection technology;
★ Adjustable needle depth and comprehensive optimization of chromatographic parameters;
★ Multiple injection modes can be set (hot needle injection, cold needle injection, and "sandwich" injection) to effectively reduce sample size
Discriminatory effect;
The sample extraction and injection speed can be adjusted arbitrarily to adapt to samples with different viscosity coefficients;
★ Accurate positioning and precise stepper motor to ensure no bending of the needle phenomenon;
★ Seamless compatibility with various gas chromatographs;
★ New IQ/OQ/PQ support services
There are two versions of automatic samplers available for different customer needs, one with 110 samples and the other with 10 samples.
HT300A high-efficiency gas-phase liquid automatic samplerSpecifications:
Sample Quantity |
110 or 10 (2 ml sample bottles) |
Injection needle capacity |
You can choose 1ul, 10ul, 25ul, 50ul or 100ul (standard configuration is 10ul) |
injection volume |
Zui can reach as little as 0.1ul |
Air volume |
Zui can reach as little as 0.1ul |
Extraction speed |
Can be set from 0.1 to 100 ul/sec |
Injection speed |
Can be set from 0.1 to 100 ul/sec |
Needle washing program |
Can be set to repeat up to 15 times, providing four types of solvents for cleaning |
Injection mode |
The repeated extraction method can effectively remove bubbles and can be set to repeat up to 15 times |
|
Dual injection mode
|
Only applicable to certain models (with front and rear injection ports), such asShimadzu GC-17/2010、Varian3400/3800 |
Efficient injection: Two types of samples can be automatically injected into two injection ports in sequence for efficient analysis. | |
Confirmation injection: The same sample can be automatically injected into two injection ports in sequence for confirmation analysis experiments. | |
Viscosity delay |
Can be set to 1 to 60 seconds |
Internal standard injection |
1. The minimum injection volume can reach 0.1ul |
|
2. The minimum air volume can reach 0.1ul |
|
3. The air gap between the sample or internal standard can be set |
program method |
10 methods that can be set for sample extraction, injection, and cleaning, with a minimum volume of 0.1ul, and 15 steps that can be set |
compatibility |
Collaborate with various atmospheric manufacturers(Agilent,Perkin Elmer,Varian,Shimadzu,ThermoSeamless compatibility, sample tray can be freely changed to the left or right. |
| control software | HT-Comsoft-AorClarityChromatography workstation |