Variable speed multipurpose oscillatorIt is a biochemical instrument for cultivating and preparing biological samples, and is an indispensable laboratory equipment for scientific research, education, and production departments such as plants, organisms, microorganisms, biological products, genetics, viruses, medicine, and environmental protection. The speed regulating multi-purpose oscillator is a floor standing type with a low center of gravity, which is stable and reliable in continuous reciprocating oscillation operation,
The main characteristics of the speed regulating multi-purpose oscillator are:
① The universal spring bottle rack is particularly suitable for the cultivation and preparation of biological samples for various comparative experiments
② Equipped with mechanical timing
③ Stepless speed regulation, easy and safe operation.
HY-2 Speed Regulating Multipurpose Oscillator
One:Variable speed multipurpose oscillatorCharacteristics and USES
The HY-2 speed adjustable multipurpose oscillator can simultaneously perform analysis on test tubes, separating funnels, triangular flasks, etc., and is equipped with a timing device for smooth and noise free operation, making it suitable for various universities and colleges Research environment protection hygiene. Epidemic prevention Oil Metallurgy Essential laboratory tools for chemical engineering.
Secondly:Variable speed multipurpose oscillatorTechnical Parameter
1.Oscillation frequency: 30-360 times/minute
2.Oscillation amplitude: 20mm
3.Working mode: continuous
4. Power supply: single-phase AC 50HZ, 220V ± 10V
5. Overall power: 150W
6. Timing: 0-120 minutes
7. Load: 20kg
8. Dimensions: 500 × 320 × 240 (mm)
3: Safety Notice for the Use of Speed Regulating Multipurpose Oscillators
Remember to follow the following safety precautions when using this product:
1. Read all user manuals.
2. The electrical rated parameters of the socket provided by the user should not be less than the electrical rated parameters of the machine and have good grounding measures.
When replacing the fuse, the plug should be unplugged from the socket.
After the motor or electrical equipment malfunctions, it should be repaired by professionals. Using non recommended accessories can cause certain quality problems.
When cleaning the machine, the power should be unplugged first.
4: Instructions for use
2. The instrument should be placed on a stable ground, with a clean and tidy environment, moderate temperature, and good ventilation.
Before using the instrument, place the speed control knob in the small position.
4. In order to ensure the smooth operation of the instrument and avoid significant vibration, all test bottle positions should be filled when bottling, and the culture medium in each bottle should be roughly equal. If there are not enough culture bottles, the test bottles can be symmetrically placed or filled with other equal amounts of solution to fill the empty spaces.
5: Maintenance and upkeep