FLOOLINE ECHOTOUCH ® The US06 intrinsic safety reflective ultrasonic level gauge achieves continuous level measurement with a range of up to 19.6 '(6m) through continuous 4-20 mA analog signals, and is set through its integrated button display module, WebCal software, or HART. These sensors are suitable for use in liquid collecting tanks containing media that are free of foam or prone to generating vapor (such as chemicals, water, waste water and oil). Typical application scenarios include collection tanks, daily supply tanks, neutralization tanks, clarification tanks, and wastewater tanks.

Product Details

● Provide measurement ranges of 6m and 12m
Reliable reflection and condensation technology measures
Aluminum shell corrosion-resistant PVDF transducer
7.6cm beamwidth applied in limited space
LCD display shows horizontal, inch, meter or percentage span
● HART communication in point-to-point and multi drop modes
● Fault safety diagnosis and selectable fault safety signal output
● Configure display through buttons or WebCal software
● Automatic temperature compensation -40 º C 80ºC

  • Range: 20cm 6m
    Accuracy: ± 0.2% up and down
    Resolution: 2mm
    Dead zone: 20.3cm
    Wave speed width: 7.6cm
    Display type: 6-digit LCD
    Supply voltage: 14-28 VDC
    Loop resistance: 500 Ω @ 24 VDC
    Signal output: 4-20mA, two-wire, HART 7
    Process temperature:- 40ºC... 80ºC
    Environmental temperature:- 40ºC... 80ºC
    Pressure: 2 bar
    Shell grade: IP66
    Shell material: Aluminum
    Shell ventilation opening: water tight membrane
    Electrical interface: 1/2 "NPT
    Sensor type: Reflective
    Sensor pad: PVDF (polyvinylidene fluoride)
    Installation interface: 2 "NPT or 2" G
    Installation gasket: N/a or Viton?
    Level: Intrinsic Safety
    Explosion proof standard: Class I, Zone 1, Groups A, B, C, and D; Second level E, F, and G groups; Level 3; Level 1 Zone 0 IIC Group, Zone 20 IIC Group
    Explosion proof certification: II 1G, EEx ia IIC Gc
    Certification: CE