The MD-S975 gas flow monitor uses MEMS flow sensing chip technology to measure the gas medium flow rate in the flow channel through thermodynamic principles. Through precise measurement techniques and responsive sensors, the MD-S975 gas flow monitor can provide highly accurate flow measurement results and operate stably even under complex environmental conditions. In addition, we also provide digital interfaces and remote monitoring functions to help customers easily obtain real-time data and perform remote configuration and control.
Product Details

Gas flow monitorTechnical Features

·12~28V DC external power supply

·4-20mA, RS485 output mode optional

·Horizontal 270 ° rotation of dial
·Working principle of heat conduction
·Support quick selection of monitoring media
·Provide digital interfaces and communication protocols
·Provide multiple rated flow range options

·3-digit digital display, easy to read measurement results

Gas flow monitorProduct Application

·Semiconductor workshop

·Petrochemical industry

·Laboratory
·Kiln pipeline


Gas flow monitorparameter indicators

Measurement medium: airNitrogen gasOxygen, hydrogen

Medium temperature: -10~60 º C

Detection method: hot type

Rated flow range: 100/300/500/800/1700 (unit SLM)

Range ratio: 50:1

Voltage resistance:Maximum 0.2~2MPa(determined based on the flow range)

Power Supplypress:DC24V

Accuracy:±2%FS

Unit: L/min (customizable)

loseDelivery method: 4~20mA/ RS485

Outgoing method: straight out, aviation plug

Shell materialPolyester plastic

Installation method: PT1/2 external thread, G3/8 internal thread, etc. (determined according to the flow range)