Computerized control panel!
captair®flexTMAll control and security information is centralized in a computerized control panel, including:
1)Fan and air flow control will issue audible and visual alarms when the air flow is imbalanced.
2)Timer, every60An alarm will be issued within an hour to remind users to check the saturation status of the filter.
3)Optional filter automatic alarm(MelecodeTMS),Suitable for organic operations.
4)Maintenance and maintenance program settings.
Filter saturation detection port!
Color beam tubes can be used to sample the air at the air outlet at the detection port to detect the saturation condition of the filter.
Fluorescent lamp!
18W,500lux,IP 68
High quality fluorescent tubes can be equipped according to the size of the fume hood1-3Root light tube. Provide high-quality lighting for chemical operations prepared for safety.
Anemometer, capable of monitoring surface wind speed!
The monitoring device for displaying surface wind speed must achieve a surface wind speed of0.4-0.6m/s(Compliant with)AFNOR NF X 15-211:2009Standard requirements).
Ergonomic design!
The tilted design of the front panel makes the operator more comfortable and provides a better view of the operation.
The oval and trapezoidal operation holes allow the operator's arms to move freely inside the cabinet, and the central protective area of the front panel provides safety to prevent chemical splashes.
The curved design of the front edge of the countertop provides comfortable arm support.
Erlab fume hoodofmain features
environmental protection!
During chemical operations, the filter will effectively filter out chemical gases, avoiding their overflow.captair®flexTMThe use of can protect the outdoor environment of laboratories, such as the environment of offices or nearby houses. With certain guidance, chemists can minimize the volatilization of chemical reagents as much as possible, and more operations can be carried outcaptair®flexTMInternally conducted.
Erlab fume hoodTechnical parameters
|
Size(mm)
Length: 63”Or 1600 mm L D H (At the operating surface) | |||
| model external internal external internal external internal | |||
| xls 633*1600 1497 790 692 1313-1495 1014 | |||
| Technical parameters | |||
| grade (According to NFX15-211:2009 standard) | Class 1 (with double-layer molecular filters per column) or Class 2 (with single-layer molecular filters per column) | Number of fans | 3 |
| Air handling capacity | 690 m3/h | Number of filter boxes | 3 |
| Average surface wind speed | 0.4 to 0.6m/s | Power consumption | 64-120W |
| voltage | Input voltage: 100-240V Internal voltage: 24-26.5V (Low voltage) | Zui high current | 2.71-4.54 A |
| volume | 58 dbA | ||
| frequency | 47-67 hz | Operation hole category | ladder-type |
|
midcapTM Simplified series without computerized control panel
| |||