E-mail
info@renhesci.com
-
Phone
13918294437
-
Address
1st Floor, Building 25, No. 69 Guiqing Road, Xuhui District, Shanghai
Shanghai Renhe Scientific Instrument Co., Ltd
info@renhesci.com
13918294437
1st Floor, Building 25, No. 69 Guiqing Road, Xuhui District, Shanghai
XLS 392 fume hoodA brief introduction
Registered filter loop system!
Computerized control panel!
captair®flexTMAll control and security information is centralized in a computerized control panel, including:
1)Fan and air flow control will issue audible and visual alarms when the air flow is imbalanced.
2)Timer, every60An alarm will be issued within an hour to remind users to check the saturation status of the filter.
3)Optional filter automatic alarm(MelecodeTMS),Suitable for organic operations.
4)Maintenance and maintenance program settings.
Filter saturation detection port!
Color beam tubes can be used to sample the air at the air outlet at the detection port to detect the saturation condition of the filter.
Fluorescent lamp!
18W,500lux,IP 68
High quality fluorescent tubes can be equipped according to the size of the fume hood1-3Root light tube. Provide high-quality lighting for chemical operations prepared for safety.
Anemometer, capable of monitoring surface wind speed!
The monitoring device for displaying surface wind speed must achieve a surface wind speed of0.4-0.6m/s(Compliant with)AFNOR NF X 15-211:2009Standard requirements).
Ergonomic design!
The tilted design of the front panel makes the operator more comfortable and provides a better view of the operation.
The oval and trapezoidal operation holes allow the operator's arms to move freely inside the cabinet, and the central protective area of the front panel provides safety to prevent chemical splashes.
The curved design of the front edge of the countertop provides comfortable arm support.
XLS 392 fume hoodofMain Features
|
Sizemm)
length:39”Or 1000 mm L D H
(At the operating surface)
| |||
| model 外部 internal 外部 internal 外部 internal | |||
| xls 392*1000 897 790 692 1313-1495 1014 | |||
| Technical Parameters | |||
| level
(According to NFX15-211:2009 standard)
|
Class 1 (Each column is equipped with a double-layer molecular filter) or
Class 2 (Each column is equipped with a single-layer molecular filter
| number of fans | 2 |
| Air handling capacity |
460 m3/h
| Number of filter boxes | 2 |
| Average surface wind speed | 0.4 to 0.6m/s | power consumption | 54-92 W |
| voltage | Input voltage: 100-240V Internal voltage: 24-26.5V (Low voltage) | Zui high current | 2.25-3.48 A |
| volume |
55 dbA
| ||
| frequency |
47-67hz
| Operation hole category | Fully open type |
|
midcapTM Simplified series without computerized control panel
| |||