Phone
18911231089
- Address
Beijing Hengaode Instrument Co., Ltd
18911231089
Dielectric constant dielectric loss tester model: HAD-JDB
1、 Compliant with standards:
ASTM D150-11 Standard Test Method for AC Loss Characteristics and Capacitance (Dielectric Constant) of Solid Electrical Insulation Materials;
GB/T1409-2006 Recommended methods for measuring the permittivity and dielectric loss factor of electrical insulation materials at power frequency, audio frequency, and high frequency;
GB/T1693-2007 Determination method for dielectric constant and dielectric loss tangent of vulcanized rubber;
GBT5594.4-2015 Test Methods for Properties of Ceramic Materials in Electronic Component Structures Part 4: Test Methods for Dielectric Constant and Tangent of Dielectric Loss Angle
2、 Host and fixture parameters:
|
Project/Model |
HAD-JDB |
HAD-JDA |
HAD-JDC |
|
|
signal source |
DDS digital synthesis signal |
|||
|
Frequency range |
10KHZ-70MHZ |
10KHZ-110MHZ |
100KHZ-160MHZ |
|
|
Signal source frequency coverage ratio |
7000:1 |
11000:1 |
16000:1 |
|
|
Sampling precision |
11BIT |
12BIT |
||
|
Signal source frequency accuracy |
3 × 10-5 ± 1 word, 6-digit significant number |
|||
|
Q-value measurement range |
1~1000Automatic/Manual Range |
|||
|
Q-value range grading |
30, 100, 300, 1000, automatic or manual shifting |
|||
|
Q resolution |
4-digit significant number, resolution 0.1 |
|||
|
Q measurement work error |
<5% |
|||
|
Inductance measurement range |
1nH~8.4H, resolution 0.1 |
1nH~140mH;Resolution 0.1 |
||
|
Inductance measurement error |
<3% |
|||
|
Direct measurement range of capacitance |
1pF~2.5uF |
1pF~25uF |
||
|
Resolution of tuning capacitor error |
± 1pF or<1% |
|||
|
Main capacitor adjustment range |
30~540pF |
17~240pF |
||
|
Resonance point search |
SCAN |
|||
|
Self residual inductance deduction function |
have |
|||
|
Direct display function for large capacitance values |
have |
|||
|
Direct reading function for dielectric loss |
have |
|||
|
Accuracy of dielectric loss coefficient |
1/10000 |
|||
|
Scope of dielectric loss testing |
0.0001-1 |
|||
|
Direct reading function of dielectric constant |
not have |
have |
||
|
Accuracy of dielectric constant |
thousandth |
|||
|
Dielectric constant testing range |
0-1000 |
|||
|
LCD display parameters |
F,L,C,Q,LT, CTBands, etc |
|||
|
accuracy |
Below 150pF ± 1pF; above 150pF ± 1% |
|||
|
QQualified preset range |
5~1000Sound and light prompts |
|||
|
ambient temperature |
0℃~+40℃ |
|||
|
Power consumption |
About 25W |
|||
|
power supply |
220V±22V,50Hz±2.5Hz |
|||
|
Polar size |
38mm/50mm (choose one) |
|||
|
Adjustable range of pole spacing |
≥15mm |
|||
|
Material testing thickness |
0.1-10mm |
|||
|
Fixture plug spacing |
25mm±0.01mm |
|||
|
Tangent value of fixture loss |
≤4×10-4 (1MHz) |
|||
|
Resolution of micrometer rod |
0.001mm |
|||
|
Test polarizer |
Material measurement diameter: Φ 38mm/50mm, adjustable thickness: ≥ 15mm |
|||
3、 Configuration:
|
Serial Number |
Standard configuration |
Unit/Quantity |
|
1 |
host |
One unit |
|
2 |
91006 fixture |
a set |
|
3 |
Inductive group |
Nine |
|
4 |
power line |
a |
|
Optional: USB module, liquid cup(Measure the diameter of the pole piece to be Φ 38mm; The inner diameter of the liquid cup is 48mm and the depth is 7mm) |
||