Welcome Customer !

Membership

Help

Beijing Hengaode Instrument Co., Ltd
Custom manufacturer

Main Products:

intelligent-mfg>Products

Dielectric constant dielectric loss tester

NegotiableUpdate on 07/18
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

GB/T1409-2006 Recommended methods for measuring the permittivity and dielectric loss factor of electrical insulation materials at power frequency, audio frequency, and high frequency;

Product Details

Dielectric constant dielectric loss tester model: HAD-JDB

1、 Compliant with standards:

ASTM D150-11 Standard Test Method for AC Loss Characteristics and Capacitance (Dielectric Constant) of Solid Electrical Insulation Materials;

GB/T1409-2006 Recommended methods for measuring the permittivity and dielectric loss factor of electrical insulation materials at power frequency, audio frequency, and high frequency;

GB/T1693-2007 Determination method for dielectric constant and dielectric loss tangent of vulcanized rubber;

GBT5594.4-2015 Test Methods for Properties of Ceramic Materials in Electronic Component Structures Part 4: Test Methods for Dielectric Constant and Tangent of Dielectric Loss Angle

2、 Host and fixture parameters:

Project/Model

HAD-JDB

HAD-JDA

HAD-JDC

signal source

DDS digital synthesis signal

Frequency range

10KHZ-70MHZ

10KHZ-110MHZ

100KHZ-160MHZ

Signal source frequency coverage ratio

7000:1

11000:1

16000:1

Sampling precision

11BIT

12BIT

Signal source frequency accuracy

3 × 10-5 ± 1 word, 6-digit significant number

Q-value measurement range

1~1000Automatic/Manual Range

Q-value range grading

30, 100, 300, 1000, automatic or manual shifting

Q resolution

4-digit significant number, resolution 0.1

Q measurement work error

<5%

Inductance measurement range

1nH~8.4H, resolution 0.1

1nH~140mHResolution 0.1

Inductance measurement error

<3%

Direct measurement range of capacitance

1pF~2.5uF

1pF~25uF

Resolution of tuning capacitor error

± 1pF or<1%

Main capacitor adjustment range

30~540pF

17~240pF

Resonance point search

SCAN

Self residual inductance deduction function

have

Direct display function for large capacitance values

have

Direct reading function for dielectric loss

have

Accuracy of dielectric loss coefficient

1/10000

Scope of dielectric loss testing

0.0001-1

Direct reading function of dielectric constant

not have

have

Accuracy of dielectric constant

thousandth

Dielectric constant testing range

0-1000

LCD display parameters

F,L,C,Q,LT, CTBands, etc

accuracy

Below 150pF ± 1pF; above 150pF ± 1%

QQualified preset range

5~1000Sound and light prompts

ambient temperature

0℃~+40℃

Power consumption

About 25W

power supply

220V±22V,50Hz±2.5Hz

Polar size

38mm/50mm (choose one)

Adjustable range of pole spacing

≥15mm

Material testing thickness

0.1-10mm

Fixture plug spacing

25mm±0.01mm

Tangent value of fixture loss

≤4×10-4 (1MHz)

Resolution of micrometer rod

0.001mm

Test polarizer

Material measurement diameter: Φ 38mm/50mm, adjustable thickness: ≥ 15mm

3、 Configuration:

Serial Number

Standard configuration

Unit/Quantity

1

host

One unit

2

91006 fixture

a set

3

Inductive group

Nine

4

power line

a

Optional: USB module, liquid cup(Measure the diameter of the pole piece to be Φ 38mm; The inner diameter of the liquid cup is 48mm and the depth is 7mm