Phone
137-0612-2102
-
Address
3rd Floor, Block A, Building 2, Gaoxin North Science and Technology Park, Changzhou City, Jiangsu Province
Changzhou Ruixin Electronic Technology Co., Ltd
137-0612-2102
3rd Floor, Block A, Building 2, Gaoxin North Science and Technology Park, Changzhou City, Jiangsu Province
1. Accurate measurement of active and reactive energy, with a measurement accuracy of 0.5 level, featuring high sensitivity, wide load, and logic anti submarine capabilities
2. Built in high-power magnetic holding relay, realizing remote opening and closing, and controlling and managing electrical terminals.
3. It has a prepaid function, and user recharge data is directly stored in the meter, which can achieve low battery warning and zero battery power off function.
4. Standard 35mm rail installation, large-scale integrated circuit design, small size, easy installation.
5. Large screen LCD display, real-time display of power information and various electrical parameter measurement values.
6. Equipped with RS-485 communication interface, optoelectronic isolation, effectively preventing destructive interference such as lightning strikes and surges, compatible with TL645 and MODBUS communication protocols.
7. Implement peak valley leveling rate function for 8 time periods, automatically convert multiple rate periods, and freeze data at regular, instantaneous, agreed, and daily intervals.
8. Accurate measurement of current and voltage; Active power, reactive power, apparent power, power factor, frequency, maximum demand and other electrical parameters.
9. Measure, record, current voltage, current, power, power factor; Record zeroing and time comparison
10. Input/output: 2-channel switch input, 2-channel switch output, convenient for external control terminals.
| specification | parameter | |
| Voltage specification | Three phase four wire: 3 × 57.7/100V 3 × 220/380V; Three phase three wire: 3 × 100V | |
| current specification | Connected through a transformer | Rated current (In): 1.5A 5A; Maximum current (Imax): 2-4 In |
| Direct access type | Basic current (Ib): 5A 10A15A 20A; Maximum current (Imax): 4-9Ib | |
| Voltage measurement range | Un±30% Un 50Hz | |
| accuracy class | Active power: 0.5S level, reactive power: 2 level, factory error controlled within 60% of the allowable error limit | |
| Starting current/creep | When there is no current in the 1% 1lb~4% Ib/current circuit and the voltage is increased by 115% Un, the output should not exceed one pulse within 10 times the time it takes to generate one pulse under the starting current | |
| power consumption | Voltage circuit: ≤ 1.5W per phase, 6vA; Current circuit, each phase ≤ 0.2VA (Ib) | |
| working environment | Working temperature: -25 ℃~66 ℃; Extreme temperature: -40 ℃~75 ℃; Relative humidity: ≤ 95% (no condensation) | |
| clock error | Warm compensated hard clock, within the working temperature range, ≤ 0.5/d | |
| battery capacity | Internal clock: 1 3.6v 1.2Ah lithium battery; External clock: 2 3V 1.4Ah lithium batteries | |
| pulse output | Constant: 400ipm/kwh-6400ip,/kwh; Width: default is 80ms ± 20ms; can be set | |
| communication interface | 1 infrared and 2 RS485; The RS485 baud rate is 2400bps; The infrared baud rate is 1200bps | |
| Overall dimensions | Height x width x thickness=91mm x 126mm x 74mm | |
Specifications and Dimensions

Install wiring