DPD residual chlorine measuring instrument

NegotiableUpdate on 09/20
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The DPD residual chlorine measuring instrument Cl 3000 measures free chlorine or total chlorine based on the DPD colorimetric method, with a measurement range of 0-10 mg/l. The DPD residual chlorine measuring instrument includes a power supply, optical sensor, and display screen, and is installed in an IP66 corrosion-resistant housing. The measurement reading is the same as the laboratory/portable photoelectric colorimetric residual chlorine meter. The output has standard 4-20mA and RS485 Modubs.

Product Details


GermanyWTWDPD residual chlorine measuring instrumentCl 3000
– DPD
colorimetry

Characteristics of DPD residual chlorine measuring instrument

· Measurement of residual chlorine or total chlorine

· Low operating costs

· Easy to operate– 30Tian free maintenance

· DPDStandard colorimetric method

· User selects measurement cycle

· Suitable for drinking water or sewage

· 2A programmable alarm

· 4-20mAandRS-485 Modbusoutput

· USEPArecognize

DPD residual chlorine measuring instrumentCl 3000based onDPDMethod for measuring free chlorine or total chlorine, with a measurement range of0-10 mg/lThe residual chlorine measuring instrument includes a power supply, optical sensor, and display screen, and is installed in oneIP66Inside a corrosion-resistant casing. The measurement reading is consistent with the laboratory/The portable photoelectric colorimetric residual chlorine meter is the same. Output with standards4-20mAandRS485 ModubsThe residual chlorine measuring instrument has a movable measuring slot and a transparent window in the optical part, which can clearly observe the reaction of the sample and reagent. The measurement accuracy is±5%(Measurement range)0-6 mg/l)And±10%(Measurement range)6-10 mg/l). The residual chlorine measuring instrument has a selectable measurement cycle time–from110Seconds to10minute. At least unmanned operation time30Oh my god. The reagents are ordered separately and supplied in powder form. They should be filled with water before use.

Technical parameters of DPD residual chlorine measuring instrument

Measuring principle

DPDStandard method for measuring residual chlorine or total chlorine

measurement range

0 – 10 mg/L Cl2(ppm)

measurement accuracy

0 – 6.00 mg/L Cl2(ppm)

±5 %Reading or±0.03 mg/L Cl2(ppm)Take the bigger one

6.01–10.00 mg/L Cl2(ppm)

±10 %reading

resolution

0.01 mg/L Cl2(ppm)

measurement period

adjustable: 110second– 10Minutes (default value:2.5Minutes)

display

LCDBacklight display

call the police

2Road programmable240VAC 2A

standard output

isolated4-20 mAAnd bidirectionalRS 485 Modbus

Operating temperature

5°…40°C

Sample pressure

0.34…10.3 bar

Sample flow rate

200 – 400 mL/min

power supply

100 – 240 VAC, 47 – 63 Hz, 150VA

Protection level

IP 66

certification

CEauthentication,ETL UL61010B-1,ETLc CSA 22.2 No. 101-1-92

weight

3.6 kgWithout reagents

Overall dimensions

406 mm x 406 mm X 229 mm

DPD residual chlorine measuring instrument