Smart meter dedicated MCU and metering chip, with measurement accuracy higher than B (1.0) level.
● LCD large screen displays total power consumption, remaining power.
4G/NB-IOT/WIFI wireless IoT communication, compatible with optoelectronic isolation RS485 communication interface, lightning protection, surge protection, and anti-interference.
Automatic power outage for overdue payments, automatic incoming calls for recharging, and reminders for minimum balance.
● Safety management functions such as remote manual power on/off, timed automatic power on/off, overload tripping, time limited current, temperature detection, infrared remote control, etc.
Built in hardware clock circuit, with local data storage, supports remote precise timing and rate setting.
Measure and record electrical parameters such as voltage, current, power, and power factor.
● Record events such as zeroing, timing, remote tripping, and remote closing.
● Independently embedded software to ensure normal operation when disconnected from the internet, realizing metering deduction and policy control, strict password verification and security authentication,
Data transmission is secure and reliable.
Built in 4G/NB-IOT/WIFI IoT wireless module, does not require a gateway to directly connect to the background, and can customize dual control and dual metering functions.
The dual circuit smart meter can independently measure and strategically control the two circuits of dormitory air conditioning and lighting sockets.
Specifications |
Parameters |
||
|
measurement
|
voltage |
Working Voltage |
220V 50Hz (80%~120%Ub) |
power consumption |
<5VA (single-phase) |
||
impedance |
>2MΩ |
||
accuracy class |
Error ± 0.2% |
||
current |
input current |
10 (60) A (startup<0.4% Ib) |
|
output current |
Maximum output current per channel 60A |
||
power consumption |
<1VA (single channel rated current) |
||
accuracy class |
Error ± 0.2% |
||
power |
Active, reactive, and apparent power, with an error of ± 0.5% (based on phenotype requirements) |
||
measurement |
electric energy |
Active energy level B (1.0) |
|
pulse |
pulse width |
80±20ms |
|
Pulse constant |
1600imp/kWh |
||
communication |
Interface and Communication Protocol |
DL/T645-2007 Custom Modbus RTU (corresponding to different series) |
|
Baud rate |
Supports 1200bps~9600bps |
||
environment |
Operating Temperature |
-25℃~+55℃ |
|
Storage temperature |
-40℃~+70℃ |
||
relative humidity |
≤ 95% (no condensation) |
||
data saving |
Data retention time after power outage: greater than or equal to 10 years |
||
continuous work |
Mean Time Between Failures (MTBF): greater than 80000 hours |
||