E-mail
2217444657@qq.com
-
Phone
18306255478
-
Address
Fenhu High tech Industrial Park, Wujiang City, Suzhou
Suzhou Ouyixin Electromechanical Co., Ltd
2217444657@qq.com
18306255478
Fenhu High tech Industrial Park, Wujiang City, Suzhou
Commonly used for construction of dual cylinder 15KW diesel generators with equal power for export
Ouyixin's diesel generators include single cylinder air-cooled diesel generators with a power range of 3KW-5KW-6-7-8-9KW, dual cylinder air-cooled diesel generators with a power range of 10-12-15KW, and four cylinder water-cooled diesel generators with a power range of 20-30-50KW.
The engine emits white smoke
Reason for malfunction: The engine cylinder body temperature is too low; The fuel tank is placed too high, and the high oil level exceeds the engine oil pump by 1.5 meters; Poor fuel quality and excessive water content; The valve and fuel injection timing are incorrect; The fuel injector needs to be adjusted;
Solution: Check the engine water temperature, turn on the engine water heater or run it under no-load (or low load) for 10-15 minutes. When the water temperature rises to 50-60 ℃, the exhaust smoke gradually returns to normal. Reduce the height of the engine fuel tank or oil level, ensuring that the difference between the high oil level in the fuel tank and the height of the engine fuel pump is within 1.5 meters, to prevent high oil pressure from causing fuel to accumulate in the engine combustion chamber, resulting in combustion failurecompleteAnd produce white smoke. Check if the fuel is qualified, and if necessary, drain the water or fuel with excessive water content that may have accumulated in the fuel tank from the bottom drain outlet, and replenish clean fuel that meets the requirements. Contact the generator manufacturer to adjust the valve and timing according to the technical specifications of the engine. Please contact the generator manufacturer for assistance; Clean and adjust the fuel injector, check for wear and tear in the injector chamber, check for problems with the plunger top, and replace damaged parts.
| Open frame dual cylinder 15KW diesel generator | |
| Unit model | EYC18000XE |
| rated power | 15KW/18.75KVA |
| Peak Power | 16KW/20kva |
| rated voltage | 230V/400v |
| rated current | 68.2/28.5A |
| rated frequency | 50Hz |
| power factor | 1.0/0.8 |
| DC voltage | 12V |
| DC current | 8.3A |
| engine type | Dual cylinder, four stroke, forced air cooling, direct injection |
| output power | 18kW/3000rpm |
| Bore × Stroke | 2-95mm×88mm |
| displacement | 1240cc |
| Engine oil capacity | 2.8L |
| Recommended lubricant model | CD grade 10W-40 |
| lubrication method | splash lubrication |
| fuel consumption rate | ≤320g/Kw.h |
| Fuel tank capacity | 25L |
| Continuous operation time (50% f load) | 8h |
| noise level | 85DB |
| Startup method | electric start |
| battery capacity | 12V-36AH maintenance free battery |
| Dimensions (length x width x height) | 1000×700×800mm |
| Weight (Kg) | 259kg |
Commonly used for construction of dual cylinder 15KW diesel generators with equal power for export
Several occasions that can be used for diesel generators
In places such as supermarkets, schools, and workplaces, diesel generator sets are installed as self owned and backup power sources to ensure normal power supply in case of sudden power outages, ensuring the stability and reliability of the power supply system. The uses of diesel generator sets are as follows:
1. Self provided power supply: no grid power supply or extremely abnormal supply, in scenarios where the required electrical power is not very high
2. Backup power supply: also known as emergency power supply, which requires high power supply guarantee in scenarios
3. Peak shaving power supply: to make up for the shortage of grid power supply, and in the scenario of power outages and restrictions
4. Mobile power bank: Mobile power banks are generally designed in the form of power vehicles and are used in mobile work scenarios. Some mobile power banks also have emergency power supply properties