Commonly used for construction of dual cylinder 15KW diesel generators with equal power for export

NegotiableUpdate on 02/07
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin
Overview
Export dual cylinder 15KW diesel generator and other power construction commonly used small diesel generators lose magnetism. The cause of the fault is that the generator is not used for a long time, resulting in the loss of residual magnetism contained in the iron core before leaving the factory, and the excitation coil cannot establish the expected magnetic field. At this time, the engine runs normally but cannot generate electricity. This phenomenon is more common in new engines, units stored in humid environments, or units that have not been used for a long time. Solution: Check the main output circuit of the generator to prevent short circuits at the output end that may cause excitation failure; Press the excitation and magnetization button if there is one; If there is no excitation button, magnetize it with a battery
Product Details

Commonly used for construction of dual cylinder 15KW diesel generators with equal power for export

Ouyixin's diesel generators include single cylinder air-cooled diesel generators with a power range of 3KW-5KW-6-7-8-9KW, dual cylinder air-cooled diesel generators with a power range of 10-12-15KW, and four cylinder water-cooled diesel generators with a power range of 20-30-50KW.

The engine emits white smoke

Reason for malfunction: The engine cylinder body temperature is too low; The fuel tank is placed too high, and the high oil level exceeds the engine oil pump by 1.5 meters; Poor fuel quality and excessive water content; The valve and fuel injection timing are incorrect; The fuel injector needs to be adjusted;

Solution: Check the engine water temperature, turn on the engine water heater or run it under no-load (or low load) for 10-15 minutes. When the water temperature rises to 50-60 ℃, the exhaust smoke gradually returns to normal. Reduce the height of the engine fuel tank or oil level, ensuring that the difference between the high oil level in the fuel tank and the height of the engine fuel pump is within 1.5 meters, to prevent high oil pressure from causing fuel to accumulate in the engine combustion chamber, resulting in combustion failurecompleteAnd produce white smoke. Check if the fuel is qualified, and if necessary, drain the water or fuel with excessive water content that may have accumulated in the fuel tank from the bottom drain outlet, and replenish clean fuel that meets the requirements. Contact the generator manufacturer to adjust the valve and timing according to the technical specifications of the engine. Please contact the generator manufacturer for assistance; Clean and adjust the fuel injector, check for wear and tear in the injector chamber, check for problems with the plunger top, and replace damaged parts.

Open frame dual cylinder 15KW diesel generator
Unit model EYC18000XE
rated power 15KW/18.75KVA
Peak Power 16KW/20kva
rated voltage 230V/400v
rated current 68.2/28.5A
rated frequency 50Hz
power factor 1.0/0.8
DC voltage 12V
DC current 8.3A
engine type Dual cylinder, four stroke, forced air cooling, direct injection
output power 18kW/3000rpm
Bore × Stroke 2-95mm×88mm
displacement 1240cc
Engine oil capacity 2.8L
Recommended lubricant model CD grade 10W-40
lubrication method splash lubrication
fuel consumption rate ≤320g/Kw.h
Fuel tank capacity 25L
Continuous operation time (50% f load) 8h
noise level 85DB
Startup method electric start
battery capacity 12V-36AH maintenance free battery
Dimensions (length x width x height) 1000×700×800mm
Weight (Kg) 259kg

Commonly used for construction of dual cylinder 15KW diesel generators with equal power for export

Several occasions that can be used for diesel generators

In places such as supermarkets, schools, and workplaces, diesel generator sets are installed as self owned and backup power sources to ensure normal power supply in case of sudden power outages, ensuring the stability and reliability of the power supply system. The uses of diesel generator sets are as follows:

1. Self provided power supply: no grid power supply or extremely abnormal supply, in scenarios where the required electrical power is not very high

2. Backup power supply: also known as emergency power supply, which requires high power supply guarantee in scenarios

3. Peak shaving power supply: to make up for the shortage of grid power supply, and in the scenario of power outages and restrictions

4. Mobile power bank: Mobile power banks are generally designed in the form of power vehicles and are used in mobile work scenarios. Some mobile power banks also have emergency power supply properties