Chlorophyll content analyzer SPAD-502Principle:
SPAD-502 Chlorophyll AnalyzerDetermine the relative amount of chlorophyll in the leaf by measuring the transmittance coefficient of the leaf in two wavelength ranges.
Chlorophyll content analyzer SPAD-502Technical specifications:
Measurement object: plant leaves
Measurement Method 2: Wavelength Optical Concentration Difference Method
Measuring area 2mm × 3mm
Sensor silicon semiconductor photodiode
Display method measurement value: 3-digit LCD display
Measurement times: 2-digit LCD display
Measurement range 0.0 to 99.9 SPAD
Memory capacity of 30 data points, automatically calculate and display the average value
Power supply: 2 AA batteries (1.5V)
Battery life measured over 20000 times
Measurement interval of less than 2 seconds
Accuracy within ± 1.0 SPAD units (SPAD values range from 0-50 at room temperature)
Repeatability within ± 0.3 SPAD units (SPAD values between 0-50)
Reproducibility within ± 0.5 SPAD units (SPAD values between 0-50)
Volume (length x width x height) 164 x 78 x 49mm
Weight 225 grams (excluding battery)
Operating environment from 0 to 50 ℃
Storage environment -20 to 55 ℃
Other alarm functions; Calibration function
Standard configuration host, calibration card, host protective cover, battery
Measurement object: plant leaves
Measurement Method 2: Wavelength Optical Concentration Difference Method
Measuring area 2mm × 3mm
Sensor silicon semiconductor photodiode
Display method measurement value: 3-digit LCD display
Measurement times: 2-digit LCD display
Measurement range 0.0 to 99.9 SPAD
Memory capacity of 30 data points, automatically calculate and display the average value
Power supply: 2 AA batteries (1.5V)
Battery life measured over 20000 times
Measurement interval of less than 2 seconds
Accuracy within ± 1.0 SPAD units (SPAD values range from 0-50 at room temperature)
Repeatability within ± 0.3 SPAD units (SPAD values between 0-50)
Reproducibility within ± 0.5 SPAD units (SPAD values between 0-50)
Volume (length x width x height) 164 x 78 x 49mm
Weight 225 grams (excluding battery)
Operating environment from 0 to 50 ℃
Storage environment -20 to 55 ℃
Other alarm functions; Calibration function
Standard configuration host, calibration card, host protective cover, battery