Welcome Customer !

Membership

Help

Beijing Keyu Xingye Technology Development Co., Ltd
Custom manufacturer

Main Products:

intelligent-mfg>Products

Bole CFX Connect fluorescence quantitative PCR instrument

NegotiableUpdate on 04/08
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

The product features of the Bole CFX Connect fluorescence quantitative PCR instrument include the commonly used dual channel detection capability and FRET channel. The excellent optical path design does not require calibration with reference fluorescent dyes. Combined with the CFX Manager Software 3.0 software, it supports absolute quantification, relative quantification, probe allele typing, and high-resolution melting curve analysis, making it a cost-effective high-performance quantitative PCR instrument.

Product Details

Bole CFX Connect fluorescence quantitative PCR instrumentHaving commonly used dual channel detection capabilities andFRETChannel, excellent optical path design without reference fluorescent dye calibration, compatible withCFX Manager Software 3.0The software supports absolute quantification, relative quantification, probe allele typing, and high-resolution melting curve analysis, making it a cost-effective high-performance quantitative toolPCRInstrument.

Bole CFX Connect fluorescence quantitative PCR instrumentProduct parameters:

model

CFX Connect

Base

CFX Connect

ramp rate

5℃/s

Heating/cooling technology

Peltier

temperature range

0-100℃

Temperature accuracy

±0.2? C

Temperature uniformity

±0.4? C (90 ° C reached in 10 seconds)

Temperature gradient range

30–100? C

Temperature gradient temperature difference range

1–24? C

excite

3 LEDs with filters

detection

3 photodiodes with filters

Excitation/detection wavelength range

450–580 nm

Melting curve resolution

0.1? C

Multi detection capability

2 more genes per well

sensitivity

1 copy of human genomic DNA

dynamic range

10 orders of magnitude

sample capacity

96

reaction volume

1-50 µ l (recommended 10-25 µ l)

Data analysis mode

Absolute quantification of standard curve, melting curve analysis, high-resolution melting curve, allele typing, endpoint fluorescence analysis?? Cq gene expression analysis, none
Limited data file merging analysis, suitable internal reference screening, relative quantification of multiple internal reference genes with amplification efficiency correction (bar chart, scatter plot, volcano plot, cluster analysis, heatmap).

data export

Excel , Word or PowerPoint user reports contain runtime settings, graphical and tabular data results, and can be printed or saved directly in PDF format; Can be connected
LIMS system.