E-mail
gaohy8210@163.com
-
Phone
13146850046
-
Address
Room 112, No. 71 Chengzhuang Road, Fengtai District, Beijing
Beijing Keyu Xingye Technology Development Co., Ltd
gaohy8210@163.com
13146850046
Room 112, No. 71 Chengzhuang Road, Fengtai District, Beijing
Bio Rad CFX96 real-time quantitative PCR instrument from the United Statesfeature
The rapid thermal cycler reduces operating time and can obtain * experimental results within 30 minutesThe optical system that is calibrated at the factory allows you to start experiments immediately without calibrationMore convenient,It can simultaneously detect 5 target genes, saving reagents and samples, obtaining more data in one experiment, and facilitating data processing
Bio Rad CFX96 real-time quantitative PCR instrument from the United StatesSupport SYBR Green or FAM fast scanning mode
After running, the results can be automatically sent as attachments to your email, and you can analyze the data anytime, anywhere,more flexible
By using the temperature gradient function, the most suitable annealing temperature can be obtained with just one run, saving experimental time
Built in multiple data analysis modes, multiple reference genes can be used for gene expression analysis. For more details, please visit
parameter
| voltage | 100-240 V | |
| frequency | 50-60 Hz , single-phase | |
| output power | zui大850 W | |
| ambient temperature | 5-40 °C | |
| weight | 21.4 kg | |
| Size (W x D x H) | 33 x 46 x 36 cm | |
| Excitation light/emission light wavelength range | 450–730 nm | |
| Fluorescence Filters | FAM/SYBR,HEX/TET/VIC,Texas Red/ROX,Cy5, Quasar 705 | |
| temperature control | ||
| sample capacity | 96 x 0.2mL reaction tube | |
| The maximum rate of temperature increase and decrease | 5.0 ° C/s | |
| temperature range | 0 – 100 °C | |
| Temperature accuracy | ± 0.2 ° C (when reaching 90 ° C) | |
| Temperature uniformity | ± 0.4 ° C (when reaching 90 ° C within 10 seconds) | |
| Temperature gradient range | 30-100 ° C, not lower than room temperature of 30 ° C | |
| Temperature gradient temperature difference range | 1 – 24 °C | |
| Low computer configuration requirements | ||
| operating system | Windows XP, Windows Vista Professional | |
| processor | 2.0 GHz | |
| Hard drives and peripherals | 20 GB hard drive, USB 2.0 interface | |
| monitor | 1024 x 768 256 colors | |
| memory | 2 GB |
| voltage |
| 100-240 V |
| frequency |
| 50-60 Hz, single-phase |
| output power |
| zui大850 W |
| ambient temperature |
| 5-40°C |
| weight |
| 21.4 kg |
| Size (W x D x H) |
| 33 x 46 x 36 cm |
| Excitation light/emission light wavelength range |
| 450–730 nm |
| Fluorescence Filters |
| FAM/SYBR,HEX/TET/VIC,Texas Red/ROX,Cy5, Quasar 705 |
| temperature control |
|
|
| sample capacity |
| 96 x 0.2mLreaction tube |
| The maximum rate of temperature increase and decrease |
| 5.0° C/second |
| temperature range |
| 0 – 100 °C |
| Temperature accuracy |
| ± 0.2 ° C (when reaching 90 ° C) |
| Temperature uniformity |
| ± 0.4 ° C (when reaching 90 ° C within 10 seconds) |
| Temperature gradient range |
| 30-100 ° C, not lower than room temperature of 30 ° C |
| Temperature gradient temperature difference range |
| 1 – 24 °C |
| Low computer configuration requirements |
|
|
| operating system | Windows XP, Windows Vista Professional | |
| processor |
| 2.0 GHz |
| Hard drives and peripherals | 20 GBHard drive, USB 2.0 interface | |
| monitor |
| 1024 x 768256 colors |
| memory | 2 GB |