Aquanova Spectrophotometers and test components provide the simplest laboratory system for measuring various parameters of samples such as water, wastewater, sewage, and the environment.
The experimental method consists of one maximum 20 Meaningful name recognition of one word length - So there is no need to remember the code or refer to the checklist. Can be stored 300 Any of the experimental methods can be passed throughbrowseThe selected documents arranged in alphabetical order are quickly recalled from memory. Frequent experiments can be conducted fromDynamic recordingCall again in the middle. The latest available data is saved in the dynamic record 8 Experimental methods.
Test Manager Specially designed for selecting experiments, editing existing experiments, creating new experiments, or deleting unnecessary experiments, helping users complete all steps.
Can quickly view any stored parameters, andDevice ManagerEquipped with a locking mechanism, it can prevent any changes to these settings without inputting a security code. The user interface is available in English ,Display in French, German, Italian or Spanish.
Aquanova All functions can be accessed from PC Software Copy on top. Enhanced the flexibility and functionality of the system. By using simple methodsSearch and downloadFunction, can be accessed from CD ROM or JenwayDownload from the website. Experiments and results can also be stored in PC Thus creating an almost unrestricted database of experimental files and result data information. Use familiarCopy and paste technology,All results can be input into a spreadsheet for analysis and display.
When supplying, Aquanova Pre installed with JenwayThe experimental combination method is compatible with almost all available water and environmental testing components. The data from the component manufacturer can be used on this device or connected PC Methods for creating these experiments ( The test manager will guide you through this step ) .
Additionally, Aquanova It can also be used as a standard single beam visible spectrophotometer by selecting the metering menu, which can display absorbance, %T Increasing functionality and flexibility with wavelength. Suitable for method development, teaching, and training fields.
|
Range |
Test Methods |
|
Test name |
Up to 20 alphanumeric characters |
|
Experimental storage |
300 methods |
|
Result storage |
50 results |
|
timer |
1 second to 24 hours / 1 second resolution / cal or save on time out |
|
coefficient |
9999.999 to 0.001 |
|
Curve correction |
up to 6 standards |
|
Clock |
Time (24 hour) and date |
|
signal communication |
RS232 - PC application software included. Down load tests from PC or website |
|
Wavelength Range |
320-1000nm |
|
resolving power |
1nm |
|
accuracy |
±2nm |
|
bandwidth |
8nm |
|
Transmittance |
0 to 199.9%T |
|
resolving power |
0.1%T |
|
Miscellaneous light |
<0.5%T |
|
accuracy |
±1%T |
|
absorbance |
-0.300 to |
|
resolving power |
|
|
concentration |
-300 to 19999 |
|
resolving power |
0.001, 0.01, 0.1, one |
|
Company |
mg/l, g/l, blank, %, ppm, pH, mg/kg, IFZ, HZ, MEq, U/ml, mU/l, u/l, µM/l, mM/l, M/l, µg/ml, mg/ml, µg/dl, mg/dl, g/dl, ng/l, µg/l |
|
Metering noise |
<1% |
|
Photometric stability |
<1%/hr |
|
display |
Custom LCD graphics |
|
output |
Analogue (0 to 1999V |
|
light source |
Tungsten halogen |
|
input voltage |
115/230V a.c. -20% +10% 50/60Hz |
|
Input power |
<50W |
|
size |
365(w) x 272(d) x 160(h) mm |
|
weight |
|
|
637 001 |
Aquanova (320-1000nm)Equipped with a power cord, 9 Road series cable (013 203), PCApplication software CD ROM (603 436)And the operating manual, 230V/50Hz . |