An aqua Doppler profiler is a new generation of ultrasonic Doppler velocimetry. Mooring system? Suitable for buoy observation. Small size? Lightweight body compass? Inclination? Pressure? The temperature sensor is equipped, and it is recorded in the internal memory. The sensor head has three transducers that are tilted at 25 degrees and uses three ultrasonic beams to provide any layer thickness (Zui 10 cm). Get the velocity profile at the number of layers. It is possible to observe for half a year (one hour interval) with a 9-mb memory and an alkaline battery with the target. And zui Additional 4gbps and battery can also extend the observation period.
Small size? Light weight
Calibration required
Ultrasonic emission intensity adjustment reduces battery depletion in shallow water
Automatic detection of vertical direction
Electroless
Because there is no projection, there are few failures / accidents
Flow profiler specification
Method |
Incoherent Doppler method |
Ultrasonic frequency |
400 kHz |
600 kHz |
1.0 MHz |
2.0 MHz |
Vertical measurement limit |
6090 m |
3040 meters |
1220 m |
410m |
Beam count |
3 |
3 |
3 |
3 |
Beam width |
3.7 degrees |
3.0 degrees |
3.4 degrees |
1.7 degrees |
Limited thickness |
28 m |
14m |
0.34m |
0.12m |
Proximity dead distance |
1.0 m~ |
0.5m~ |
0.2 M~ |
0.05 M~ |
Tuple |
3Hz |
4 Hz |
7 Hz |
23 Hz |
Measuring cell count |
1128 |
Little sampling |
1Second |
Range |
0± 10 m / S |
Accuracy of measurement |
The measurement value is |
Intensity range |
90 dB |
Reflectance intensity resolution |
0.45 DB |
Wave measurement specifications
Ultrasonic method |
Incoherent Doppler method |
Data content |
Water pressure and velocity of each beam |
Measuring layer thickness |
0.5mOptional |
Interval |
Profiler interval |
Sample number |
5121024, 1200, 248, 2400 |
Sampling rate |
1、 2Hz |
Hardware specification
Material |
Delline plastic?Polyurethane, plastic, titanium screws Deep sea titanium?Dellin plastics |
Dimensions |
75 mm in diameter and 463 mm in length |
Weight |
Standard: 2.2 kg (1, 2 MHz), 2.9 kg (600 kHz), 3.4 kg (400 kHz) Deep sea: 6 to 10 kg |
Breakdown performance |
For standard use: 300m, deep sea: 6000 m |
Power specification
Input power |
915 VDC |
Outgoing strength |
0.320W |
Power consumption |
0.21.5 w (measuring time), 0.0003 w (standby) |
Internal battery |
13.5v-50whAlkaline battery 11.6 v-150wh lithium battery |
Communication specification
Morphology |
RS232C、 RS422 |
Baud rate |
300115200 BPS |
External equipment connection
Input channel |
2Channel |
Power supply |
5VOr 12V |
Input voltage |
05 V |
Resolution |
16Bit a / D |
Data logger specifications
Storage capacity |
9 MB(standard), + 32 / + 176 / + 352 MB extension or 4 gBSD |
Interval |
1Intermittent measurable |
Memory mode |
Standard mode (stop with full data) Lap mode |
Memory contents |
Date, time, profile number Three component velocity profile, reflection intensity, water temperature, hydraulic pressure, tilt, orientation |
Mounting sensor specifications
Temperature |
Type |
Thermistor |
|
Range |
-440 degrees centigrade |
|
Accuracy |
± 0.1 |
|
Resolution |
0.01 degrees centigrade |
Compass |
Type |
Magnetic resistance (MR) equation |
|
Range |
0360 degrees |
|
Accuracy |
± |
|
Resolution |
0.1 degrees |
Slope |
Type |
Electrolyte type |
|
Range |
0~±30° |
|
Accuracy |
± 0.2 degrees |
|
Resolution |
0.1 degrees |
Depth |
Type |
Piezo resistance |
|
Range |
100 mStandard |
|
Accuracy |
± 0.5% FS |
|
Resolution |
0.005% FS |
Aquadopp Profiler HR
Optional high resolutionHRAqua dope profiler1 cmOn the unit scale below8 HzIt can be manipulated as a high precision profiler with sampling rate.
This function is bottom1~2mResearch on the boundary layer study and low energy environment research such as lakes and estuariesHRThe profiler succeeded in capturing a detailed flow field that could not be any other instrument.
Z-Cell
Conventional Aqua dope profilers cannot capture the flow of equipment proximity. Aqua DOPZCell. Aqua dope profiler600 kHz、1.0 MHzA transverse beam for measuring the flow velocity of the measuring instrument near the plateZEquipped with cells. Sea level?It has become possible to measure the boundary layer.
* the contents may be changed without notice. Please contact our representative for details.
JFE
All rights reserved by the JFE whole line.
Nippon KawaJFEUltrasonic thickness meter/Hardness
Normal type:TI-56K、TI-56L
High precision type:TI-66W
Special type:TI-56H、TI-56F、TI-66C
Film thickness6000 FN1
Flight hardnessSH-21A、SH-22
Nippon KawaJFEGeki
MK-210HE II、MK-210HE II AUTO、MK-21、MK-64
Shock absorber
Pu-611d - pu-611e
Pu-616d
Pu-621d to pu-621e
Pu-626d to pu-626e
Normal type:PU-601R、PU-611E、PU-621E、PU-616E、PU-626E、PU-6ALSF、
High temperature typePU-8ALT6、PU-8ALSF、PU-671D、PU-8ANSF
Low frequency and high sensitive type:PU-6GHT6
Waterproof type:PU-7ALT6、PU-7SLT6
Honbo explosion type:PU-441、PU-451、PU-446、PU-456
Nippon KawaJFEDeterioration degradation:
AE-210SE、MK-720
Nippon KawaJFEFlight serviceLow speedShojoCuttingVessel:
MK-560
Dry powder
MK-95
Nippon KawaJFEInput water level mark/Horizontal tick:
SL-180B、SL-600B、SL-180C、SL-600C、SL-232B、SL-500B、SL-852C、SL-312C、SL-710C、ML-122
Nippon KawaJFEOptical level meter/Horizontal tick:
FL-30B、FL-30C
Nippon KawaJFEWater recycle
QW-3000、QW-4000
Nippon KawaJFEUltrasonic flow meter:
OCM-Pro CF、PCM4、ATENAS
Nippon KawaJFETonbo
SD-20、SD-40
Nippon KawaJFEMolten tin:
OD-10
Nippon KawaJFEDischarge current
FD-10、FD-20
Nippon KawaJFEOkenari
ATHW-05B(P)、ATHW-1B(P)、ATHW-1.5B(P)、ATHW-2B(P)、ATHW-3B(P)、ATHW-5B(P)
ATHW-05M(P)、ATHW-1M(P)、ATHW-2M(P)、ATHW-3M(P)、ATHW-5M(P)
ATH-L01
Nippon KawaJFEWeight meter:
CB-1、CB-2-5、CB-2-10、CB-3-10、CB-3-20、CB-4
SummaryHR-2、HR-5、HR-10、HR-20、HR-30、HR-50、HR-100、HR-200、HR-300
Nippon KawaJFEDouble gate desk
LU-40、LUD-40、LU-120、LUD-120、LU-240、LUD-240、LU-450、LUD-450
Calculate the amountERM-400SP
JFE CorporationSendQuantificationA deskNormalCarriage:
KC-V
Nippon KawaJFESummary
TM-H10、TM-H20、TM-V20、TM-V50、TM-V100、
TM-V20-A、TM-V50-A、TM-V100-A、TM-V20-B、TM-V50-B、TM-V100-B
SPL-10、SPL-20、SPL-30、SPL-50、SPL-100、SPL-200
KM-50L、KM-100L、KM-200L、KM-500L
KM-1、KM-2、KM-5、KM-10
KS-1、KS-2、KS-5、KS-10、KS-20、KS-30
The reaction forceSP-T50、SP-T100、SP-T200、SP-T500、SP-T1K、SP-T2K
DF-200LA、DF-200LA-KE、DF-500LA、DF-200LA-KE、DF-1、DF-2、DF-5、DF-10、DF-1-KE、DF-2-KE、DF-5-KE、DF-10-KE
HRII-10、HRII-20、HRII-30、HRII-50-N、HRII-100-N、HRII-200、HRII-300
IR-20、IR-30
ZT-1A、ZT-2A、ZT-20、ZT-30
ZR-1A、ZR-2A、ZR-5、ZR-10、ZR-20、ZR-30、ZR-20-KE、ZR-30-KE
BH-10、BH-20、BH-30、BH-40、BH-50、BH-60
CT-10B-F、CT-20B-F、CT-30B-F
KB-20L、KB-30L、KB-50L、KB-100L、KB-200L、KB-300L、KB-500L
Japan River & Ocean
Underwater deskSFIDA UCW
Compact water temperature meterDEFI-T、DEFI-L、DEFI-D10、DEFI-D20、DEFI-D50、DEFI-D5HG、DEFI-D20HG、DEFI-D50HG、 (DEFI-IF、Defi if HSJuncture
Rinko w(AROW2-USB)RINKO I(ARO-USB)RINKO I D(ARO1-USB)RINKO II(ARO-CAR/CAD)RINKO II D(ARO-CAR/CAD)RINKO III(ARO-CAV)
RINKO-Profiler:ASTD100、ASTD101、ASTD102、ASTD103、ASTD150、ASTD151、ASTD152、ASTD153
AAQ-RINKO:AAQ170、AAQ171、AAQ172、AAQ175、AAQ176、AAQ177Uchiku deskPC-11Flight attendantH-11)AAQ-IF)
Velocity meterINFINITY-EM、INFINITY-Deep
MineINFINITY – WH
Water temperatureINFINITY-CT、INFINITY-CTW
ShohakuINFINITY-CLW、INFINITY-Turbi
Light photometricMulti-Exciter:MFL05W-USB、MFL10W-USB、MFL05W-CAD、MFL10W-CAD
Particle multiplierParticle-Counter:IM-CA-X、IM-IFContact
Temperature, depth and depth:COMPACT-CTD Lite、ACTD-DF
SmallDie ZukunftCompact-LW:ALW-CMP
Magnetic flux velocity:AEM1-D、AEM213-D、ACM2-RS、ACM3-RS、ACM-4IF
Hypervelocity flow velocity Atlas 、AWAC、Aquadopp、DW-Aquadopp、VECTOR、Vectrino、Vectrino Profiler
Vertical profiler for turbulence measurement:VMP-250(Turbo VMP)
Modular autonomous turbulence measurement profilerMicroRider:MR-1000、MR-6000
ATENASFlowmeterATENAS(传感器:KTT-200、FTT-200、FTT-28)