Welcome Customer !

Membership

Help

Shanghai Yudong Electronic Technology Co., Ltd
Custom manufacturer

Main Products:

intelligent-mfg>Products

Shanghai Yudong Electronic Technology Co., Ltd

  • E-mail

    1375312008@qq.com

  • Phone

    18121126516(微信同号)13301881771

  • Address

    Building 10, 4th Floor, Block F, No. 1188 Lianhang Road, Minhang District, Shanghai

Contact Now

Acetic acid detection tube 145 Propyl acetate

NegotiableUpdate on 06/06
Model
Nature of the Manufacturer
Producers
Product Category
Place of Origin

Overview

Acetic acid detection tube 145 Propyl acetate, measuring range 20 to 500 ppm, is a semi quantitative method, but it has large errors, multiple interference factors, and the test paper itself is prone to failure. At present, commonly used test strips for detecting ammonia, organophosphorus pesticides, carbon monoxide, phosgene, hydrogen cyanide, hydrogen sulfide, formaldehyde, acetaldehyde, nitrogen dioxide, hypochlorous acid, hydrogen peroxide, etc. The tracheal examination method has the characteristics of simplicity, speed, and direct reading

Product Details

乙酸检测管145 Propyl acetate

Propyl acetate No.145

CH3CO2CH2CH2CH3(CH3CO2C3H7)

乙酸检测管145 Propyl acetate

Performance

Measuring Range

20 to 500 ppm

Number of Pump Strokes

2

Correction Factor

1

Sampling Time

4 minutes per pumpstroke

Detecting Limit

4 ppm (n=2)

Color Change

Yellow → Blackishbrown → Pale blue after few minutes

Reaction Principle

CH3CO2CH2CH2CH3+ Cr6++ H2SO4→ Cr3+

Coefficient ofVariation

15% (for 20 to 100ppm), 10% (for 100 to 500 ppm)

ShelfLife 2 Years
Correctionsfor
temperature & humidity
Temperature correction isnecessary
Store the tubes at cool and darkplace.

Possible coexisting substances and theirinterferences (NOTE)


Substance

Concentration

Interference

Change color by itself

Alcohols

-

Plus error

Produce blackishbrown
then turns to pale blue

Ketones

-

Plus error

Produce blackishbrown
then turns to pale blue

Esters

-

Plus error

Produce blackishbrown
then turns to pale blue


Othersubstance measurable with this detector tube


Calibration gasgeneration Diffusion tube method



TLV-TWA TLV-STEL Explosive range
200ppm 250ppm 1.7to 8%