7725i injection valveIn addition to the various functions of the widely used 7125 injection valve, it also has the following five functions:
(1) During the sampling/injection conversion, the mobile phase remains continuous (with no interruption in the flow path, as per Rheodyne's patented technology MBB)
(2) The pressure selector button behind the handle can make sealing control very easy;
(3) The range of pipeline connection angles has increased, making it easier to connect and use the injection valve;
(4) Equipped with an internal trigger (position sensing switch, limited to type I injection valves with suffix);
(5) Optional 2 microliter built-in ultra micro quantitative tube and accessories
The new rotor seal allows for 30000 injections. The patented design of the needle path allows the micro injector needle to reach the edge of the quantitative ring without losing the sample. The 7725i has a built-in sensor that provides a start signal for the integrator and workstation.

High performance liquid chromatography HPLC detection scheme for doxycycline hydrochloride
-Sample processing procedure-
Accurately weigh an appropriate amount of doxycycline hydrochloride reference substance, add an appropriate amount of 0.01mol/L hydrochloric acid solution, dissolve by ultrasound, and dilute with 0.01mol/L hydrochloric acid solution to a solution containing approximately 1mg doxycycline hydrochloride per 1ml. Shake well, filter through a 0.45 µ m organic system filter membrane, accurately measure 20 µ L, inject into a liquid chromatograph, and record the chromatogram.
-Chromatographic conditions-
Chromatographic column: C18, 4.6 mm*250 mm, Particle size 5 µ m
Mobile phase: Acetonitrile: Acetate buffer solution=25:75
Wavelength: 280nm
Flow rate: 1.0mL/min
Instrument configuration:
Please click to view the image details
|
LC-10Tvp high-pressure constant current infusion pumpIt is a multifunctional constant current infusion pump with high flow accuracy, corrosion resistance, and high pressure resistance...... |
|
SPD-10Tvp UV detectorA dual beam monochromatic system composed of imported deuterium lamps, photovoltaic cells, and 1200/mm concave gratings...... |
|
8725i injection valveIt is a six way valve in which the sample is loaded through an embedded needle track in front of the valve...... |
|
Vertex C18 ColumnFeaturing high surface coverage and complete tail sealing, it is suitable for chromatographic analysis in a wide range of pH values from 1.5 to 10.0...... |
|
AP-01P oil-free vacuum pumpIt is a small vacuum pump with a lightweight and beautiful appearance, high efficiency, low noise, and adjustable pressure...... |
|
VI2010 Chromatography WorkstationBreaking through the bottleneck of current domestic chromatography software only having serial port communication, truly realizing USB interface communication...... |
There are multiple models to choose from, including 10 and 6 ports
Stainless steel or material
Working pressure 35.0MPa (5000psi)
Manual or remote control operation
electronic control

High performance liquid chromatography HPLC detection scheme for doxycycline hydrochloride
-Sample processing procedure-
Accurately weigh an appropriate amount of doxycycline hydrochloride reference substance, add an appropriate amount of 0.01mol/L hydrochloric acid solution, dissolve by ultrasound, and dilute with 0.01mol/L hydrochloric acid solution to a solution containing approximately 1mg doxycycline hydrochloride per 1ml. Shake well, filter through a 0.45 µ m organic system filter membrane, accurately measure 20 µ L, inject into a liquid chromatograph, and record the chromatogram.
-Chromatographic conditions-
Chromatographic column: C18, 4.6 mm*250 mm, Particle size 5 µ m
Mobile phase: Acetonitrile: Acetate buffer solution=25:75
Wavelength: 280nm
Flow rate: 1.0mL/min
Instrument configuration:
Please click to view the image details
|
LC-10Tvp high-pressure constant current infusion pumpIt is a multifunctional constant current infusion pump with high flow accuracy, corrosion resistance, and high pressure resistance...... |
|
SPD-10Tvp UV detectorA dual beam monochromatic system composed of imported deuterium lamps, photovoltaic cells, and 1200/mm concave gratings...... |
|
8725i injection valveIt is a six way valve in which the sample is loaded through an embedded needle track in front of the valve...... |
|
Vertex C18 ColumnFeaturing high surface coverage and complete tail sealing, it is suitable for chromatographic analysis in a wide range of pH values from 1.5 to 10.0...... |
|
AP-01P oil-free vacuum pumpIt is a small vacuum pump with a lightweight and beautiful appearance, high efficiency, low noise, and adjustable pressure...... |
|
VI2010 Chromatography WorkstationBreaking through the bottleneck of current domestic chromatography software only having serial port communication, truly realizing USB interface communication...... |