What to do if the gasoline generator cannot start:
Firstly, check if the engine oil and gasoline are newly added. If they are not, they have been added for more than three months and need to be poured out and replaced. Oil and gasoline have a shelf life of only three months, and oil and gasoline that have exceeded three months have lost their stickiness and have no effect.
Check if the engine oil and gasoline of the generator are fully filled. If they are not filled, the generator will not start or ignite.
If all of the above have been achieved, then check if the spark plug ignites. If it does not ignite, remove the spark plug and dip it in some gasoline before installing it to see if the generator ignites. If it ignites, start it up.
The generator is difficult to start when it comes to use because it is not frequently used. The oil level in the carburetor drops, causing decay and blocking the oil hole. The second reason is that the engine oil has flowed back to the oil pan after a long time of not starting. At the beginning of the engine, there is no oil lubrication, and the cylinder pressure cannot be reached. At this time, too much gasoline (cold oil) enters and does not burn, causing the spark plug to choke (the spark plug is wet). Remove the spark plug, wipe it clean, burn it with a lighter for a while, or directly replace it with a new spark plug. (These are usually these reasons, remember that it can also be used in many cars.)
Explain the gasoline generator:
When sound waves are incident on the interface of any object, a portion of the sound energy will enter the object to some extent and be absorbed. The sound absorption capacity of a material is represented by its sound absorption coefficient, which is the percentage of the absorbed sound energy to the incident sound energy. In case of an electric shock accident, please first connect the ground wire and use unleaded gasoline of 90 # or above when using this machine. When refueling, first remove the fuel tank cap (rotate counterclockwise), then add fuel and observe the fuel level gauge on the tank at all times. Do not remove the fuel filter from the refueling port when refueling. When refueling, the generator must be stopped and be very careful of the surrounding fireworks. Do not add oil beyond the top of the oil filter.
18/20KW gasoline generator unit needs to be backup and portable for power outage
| Unit model | EYC25000E | |
| generator | excitation method | AVR voltage automatic regulation |
| power peak | 20KW/25KVA | |
| Power rating | 18KW/22.5KVA | |
| rated voltage | 230V/400V | |
| current | 78A/26A | |
| frequency | 50HZ | |
| phase number | Single phase/Three phase | |
| power factor | 1/0.8 | |
| insulation class | F | |
| engine | Engine model | DHT720E |
| Cylinder diameter x stroke | 82x71mm | |
| displacement | 999cc | |
| fuel consumption | ≤374g/kw.h | |
| ignition method | Electromagnetic ignition | |
| engine type | V-shaped twin cylinder four stroke air-cooled | |
| fuel | 90 # or above unleaded gasoline | |
| Oil quantity | 2.0L | |
| Startup method | electric start | |
| Attachment configuration | Fuel capacity | 30L |
| warning device | have | |
| Fuel gauge | have | |
| Control Panel | standard configuration | |
| Wheel accessories | have | |
| battery capacity | 12V-45AH maintenance free battery | |
| other | noise | 85db |
| unit size | 1050x680x720mmmm | |
| Continuous working hours | 10h | |
| weight | 215kg |