| Performance |
MeasuringRange |
0.5 to 1 mg/l |
1 to 14 mg/l |
14 to 28 mg/l |
Number of Pump Strokes |
2 |
1 |
1/2 |
CorrectionFactor |
1/2 |
1 |
2 |
SamplingTime |
1 minute per pumpstroke |
||
DetectingLimit |
0.1 mg/l (n=2) |
||
ColorChange |
Orange → DarkGreen |
||
ReactionPrinciple |
Petroleum oil + Cr6++ H2SO4→Cr3+ |
||
| Coefficient ofVariation | 10% (for 1 to 4 mg/l), 5% (for 4 to 14 mg/l) | ||
| ShelfLife | 3Years | ||
| Correctionsfor temperature & humidity |
Unnecessary | ||
| Store the tubes at cool and darkplace. | |||
| Possible coexisting substances and theirinterferences | (NOTE) |
Substance |
Concentration |
Interference |
Change color by itself |
Sulfur dioxide |
500 ppm |
Plus error |
Produce greenhouses |
Hydrogen sulfide |
500 ppm |
Plus error |
Produceblackish brown |
Acetylene |
3% |
Unable tomeasure |
Produce blackishbrown |
Propane |
0.2% |
Unable tomeasure |
Produce blackishbrown |
Organic solvents |
- | Plus error |
Produce greenishbrown |
| Othersubstance measurable with this detector tube |
Substance |
Correction Factor |
Pump Strokes |
Measuring Range |
Petroleumbenzene |
1.0 |
1/2, 1 or 2 |
0.5 to 28 mg/l |
Petroleumether |
1.0 |
1/2, 1 or 2 |
0.5 to 28mg/l |
| Calibration gasgeneration | Staticgas dilution method | |
| TLV-TWA | TLV-STEL | Explosive range |
| - | - | - |