Alternative Model XF-2S
Automatic dual cup open and closed flash point tester
AF-2S
The AF-2S automatic double cup flash point tester is the latest product assembled and produced by our company to meet the needs of domestic use. The instrument has the advantages of multiple testable items and high degree of automation, and is widely used in industries such as petrochemicals, plastics, civil aviation, commercial inspection, and power systems.
1、 Instrument features:
1. Multiple testing items: The same instrument can be combined according to user needs and can perform two or more flash point tests simultaneously.
① Tektronix closed cup method flash point determination: in accordance with ASTM D56 standard.
② Binsky Martin closed cup method for flash point determination: in accordance with ASTM D93 standard.
③ GB 261 Closed Cup Method for Flash Point Determination: Complies with GB 261 standard.
④ Cleveland Open Cup method for flash point/ignition point determination: in accordance with GB/T 3536 and ASTM D92 standards.
⑤ GB/T 267 Open Cup Method for Flash Point Determination: Complies with GB/T 267 standard.
2. High degree of automation: Whether it is flash point or ignition point determination, as long as the relevant parameters are set and the START button is pressed, the entire test process will be automatically carried out.
3. Any model can simultaneously test two sets of samples, conduct comparative experiments, or take the average value.
4. The large screen LCD display is easy to operate, with a rich interface, and the experimental process and measurement data are all clear at a glance. The printer automatically prints the data results.
5. The main electrical components of the control and measurement departments are all imported, ensuring the reliability and stability of the instrument.
6. The ignition device of the operation department can be selected from electronic ignition and gas ignition methods (users can choose one of the corresponding methods according to the situation).
7. The overall design of the instrument is compact, small, and aesthetically pleasing, receiving high praise from users.
8. The instrument has self diagnostic and alarm functions, which further ensures the safety of the testing process.
9. The instrument is equipped with a standard RS-232C communication interface, which can be connected to the central control computer for networked quality management.
2、 Instrument specifications:
1. Applicable standards:
① Tektronix closed method flash point determination: in accordance with ASTM D56 standard.
② Binsky Martin closed cup method for flash point determination: in accordance with ASTM D93 standard
③ GB 261 Closed Cup Method for Flash Point Determination: Compliant with GB 261 Standard
④ Cleveland Open Cup method for flash point/ignition point determination: in accordance with GB/T3536 and ASTMD92 standards
⑤ GB/T 267 Open Cup Method for Flash Point Determination: Complies with GB/T267 Standard
2. Instrument form: desktop, dual test furnace (all stainless steel shell).
3. Temperature control:
Open cup method for flash point determination at 0 ℃~400 ℃; Temperature control accuracy ± 0.1 ℃.
Closed cup method for flash point determination at 0 ℃~300 ℃; Temperature control accuracy ± 0.1 ℃.
Tektronix closed cup method for flash point determination at 0 ℃~300 ℃; Cooling function can also be added (for electronic cooling below 0 ℃), with a temperature control accuracy of ± 0.1 ℃.
4. Display: Large LCD screen.
5. Printer: Built in needle printer.
6. Flash point detection method: The open cup method uses flame ion detection to determine the flash point, while the closed cup method uses high-sensitivity thermocouple detection to determine the flash point.
7. Display content:
① Control the temperature and set the expected flash point temperature.
② Test results and average values.
③ Fault prompt screen.
④ Various model parameters and pressure settings.
8. Experimental data storage: 100 sets for each model group.
9. Electricity consumption: 800W × 2
10. Dimensions: (Instrument body) 400 (W) * 380 (D) * 350 (H) mm
11. Weight: Approximately 20kg
3、 Standard configuration:
1. 1 built-in printer
2. 2 signal connection wires
3. 2 sample cups (optional according to the test model)
4. 1 ignition gun (excluding electronic ignition)
5. 2 fuses
6. Two trachea
7. 1 power cord
8. 4 sealing O-rings (for Tektronix closed method)