-
E-mail
yztpdq@yztpdq.com
-
Phone
15366862628
-
Address
No. 2 Guotai Road, Baoying County, Jiangsu Province
Yangzhou Top Electric Technology Co., Ltd
yztpdq@yztpdq.com
15366862628
No. 2 Guotai Road, Baoying County, Jiangsu Province
Intelligent Cable Fault Tester Provided by Yangzhou Topu Electric Technology Co., Ltd., Technical Parameters
Open circuit fault: If the insulation of the cable is normal, but the voltage cannot be transmitted normally due to conductor reasons, it can be considered as an open circuit fault, such as the core wire or ground wire appearing to be broken but not broken, a large line resistance in one part of the core wire, and a broken core. Simple open circuit faults are rarely seen, and are mostly manifested as coexisting with low or high resistance faults.
Low resistance fault: If the insulation medium of the cable is damaged, a type of phase to phase or phase to ground fault that can be directly tested using the "low voltage pulse method" is called a leakage low resistance fault. It is usually called a low impedance fault. The general resistance value is below several hundred ohms. If the resistance value is "zero", it is called a short circuit fault, which is a special case of low resistance fault.
Product Features
1) Windows operating system, touch based operation mode, scientific cable management, real-time report generation;
2) System functions: fault distance measurement, fault point location, propagation speed testing, cable path search, burial depth detection, etc;
3) Testing methods: low voltage pulse, flashover method, audio method, acoustic magnetic synchronization method, valley value method, peak value method, electromagnetic induction method, etc;
4) Display control: Flash tester: 12 inch industrial grade computer control, built-in 12V/10Ah DC power supply, can work continuously for 10 hours; Others are controlled by a microcontroller and displayed on a pointer meter;
5) Test range: Test distance: 60km, detection depth: 2-5m;
6) Measurement accuracy: Rough measurement error: ± 10m or 1% (relative value), precision measurement error: ± 0.2m (fixed point, path, depth);
7) Sampling frequency: 100MHz, minimum resolution 0.5m (100m/us)
8) Sampling method: Fully automatic continuous sampling, never missing any discharge waveform
9) Low voltage pulse: Width: 0.1uS and 2uS Amplitude: 100Vpp
10) Output power: Path power: 100W, impulse power: 0-400W
11) Impulse high voltage: 0-35kV
12) Short circuit current: 0-320mA
13) Burn through power: 0-1225J
Technical Specifications
1. 12 inch industrial grade computer control, touch based operation mode;
2. XP operating system, powerful cable management system, automatic generation of test reports;
3. Equipped with functions such as distance measurement and speed measurement;
4. 100MHz sampling frequency, minimum resolution 0.5m (100m/us);
5. Fully automatic continuous sampling, never missing any discharge waveform;
6. Testing methods: flashover sampling, low voltage pulse sampling
7. Pulse amplitude: 100Vpp
8. Pulse width: 0.1uS and 2uS
8. Measurement distance: Smax: 60km Smin: 15m
9. Measurement error: Rough measurement error: ± 10m Rough measurement relative error: ± 1%
(DL/T849.1-2004 stipulates that the cable length shall not exceed ± (1% L+20) m, where L is the cable length.)
10. Power supply: Built in 12V/10Ah DC power supply, capable of continuous operation for 4 hours
It can also be connected to an external AC 220V 50Hz power supply
Information organization: Yangzhou Topu Electric Technology Co., Ltd
