Xi'an Liding Optoelectronics provides a variety of infrared optoelectronic countermeasure testing equipment, including portable infrared emissivity measuring instruments, handheld infrared emissivity measuring instruments, digital infrared radiometers, infrared radiation power meters and other series of products. Welcome to inquire.
RLK650 Pro portable infrared emissivity measuring instrument
Measurement principle: Integral hemispherical reflection method measurement principle;
Measurement band: Dual band measurement of 3-5um&8-14um;
Color touch screen design, with a clear Chinese interface at a glance;
Supports Micro SD card storage and TXT file format for easy data analysis in the future;
Compared with RLK650, it has a smaller volume, lighter weight, faster measurement speed, and higher measurement efficiency.
On site evaluation of infrared performance of aircraft, ships, and vehicles
Research on Infrared Coating Materials
RLK650 portable infrared emissivity measuring instrument
Measurement principle: Directional Hemisphere Reflection (DHR), 20 °± 1 ° incidence;
Measurement band: Dual band, 3-5 μ m&8-12 μ m;
Repeatability: ≤ 0.01;
● Portable design: Good ergonomic appearance design, good operating feel;
Color touch screen: Chinese character interface, touch operation, clear at a glance, one click measurement, easy to operate;
● Digital storage: MicroSD card, maximum 2048 records, divided into 8 groups, TXT file format, convenient for subsequent analysis on PC.
Research on Infrared Characteristics of Stealth Coating Materials
On site evaluation of infrared stealth performance of aircraft, ships, and vehicles
RLK651 Handheld Infrared Emissivity Measuring Instrument
Measurement principle: Directional Hemisphere Reflection (DHR), 20 °± 1 ° incidence;
Measurement band: 2-22um;
Repeatability: ± 0.02;
Measurement time:<10 seconds (2 data acquisitions per measurement)
Preheating self-test time: 180s
Working temperature: 0 ℃ -+45 ℃
Data recording: The last 32 measurement records are convenient for measurement comparison.
◇Far infrared radiation coating
◇ Far infrared ceramic powder
◇ Far infrared fiber
Thin layer graphene infrared heat dissipation material
◇ Aluminum silicate ceramic fiber cotton
RLK656 Infrared Emissivity Measuring Instrument
Principle of Integral Hemisphere Reflection Method for Measurement;
● Easy to operate, high measurement accuracy, and fast measurement speed;
Color touch screen design, with a clear Chinese interface at a glance;
● Integrated design, all aluminum brushed panel, simple and atmospheric;
The sample holder is adjustable and suitable for testing multiple specifications of samples;
● Comes with a sample storage box and sample rack for easy storage.
Research on Infrared Materials in Universities/Institutes
Research on Industrial Infrared Functional Materials
◇ In/out testing of infrared functional material samples
◇ Professional testing institutions measure the infrared emissivity of samples
RLK600 Digital Infrared Radiometer
Digital infrared radiometer, tested and calibrated by the first level metrology station of the National Defense Science and Technology Commission;
● Portable design: All components and accessories of RLK600 are packed in an aluminum instrument box for easy carrying and transportation;
Integrated design: Optics, chopper, phase-locked, and A/D are all integrated into the head, requiring only one cable to connect to the computer;
RS-422 interface: The transmission of control commands and data adopts the RS-422 standard, with a long transmission distance and strong anti-interference ability;
Specialized software: It has three major functions: measurement control, data processing, and product calibration, and runs on the Windows operating system.
Infrared radiation characteristics of aircraft engines
◇ Infrared radiation characteristics of engine
Infrared radiation characteristics of infrared decoy bombs
◇ Infrared radiation characteristics of infrared markers
Infrared radiation characteristics of pyrotechnic devices
Infrared radiation characteristics of industrial radiation sources
RLK605 Infrared Radiation Power Meter
Measurement band: 2-25um;
Measurement sensitivity: 0.1W;
● Aiming method: laser point indication aiming;
Operation mode: Manually input the working distance, and the screen displays the radiation power intuitively.
◇ Industrial and medical infrared radiation power measurement
RLK607 Contact Infrared Radiometer
● Interface display: Directly display the infrared radiation power value and material surface temperature value;
Measurement band: 2-30um;
Measurement method: contact measurement;
● Portable design: compact in size and weighing only 700g, convenient to carry;
● OELD monochrome screen: clear at a glance, one click measurement, easy to operate;
Power interface: Standard miniUSB charging port, easy to use.
◇ Used for measuring the infrared radiation characteristics of various materials such as infrared coatings, infrared functional ceramics, and textile products.