What are the common faults of electronic weighing scales
Date: 2025-11-13Read: 31
Electronic weighing scales, as important equipment for industrial weighing, are widely used in logistics, warehousing, mining, chemical and other fields. Its common faults can be divided into five categories: mechanical structure, sensors, instrument displays, electrical connections, and environmental interference. The following is a detailed fault analysis and solution:1、 Mechanical structural failure
1. Deformation or sinking of the weighing scale body
-
phenomenonThe four corners of the scale body are uneven, causing significant fluctuations in data during weighing, or the scale body sinks after long-term use.
-
reason:
- The foundation construction is not standardized (such as the foundation is not compacted and the drainage is not smooth).
- Overloading or long-term overloading of vehicles can cause deformation of the weighing body.
- The sensor support point is loose or damaged.
-
Solution:
- Basic inspection: Use a spirit level to measure the height difference of the four corners of the scale body. If it exceeds 5mm, the foundation needs to be readjusted.
- Repair the scale body: Correct the deformed parts or replace the structural components of the scale body.
- Overload restriction: Set up load limit signs to prevent vehicles from driving overweight.
2. Limit device failure
-
phenomenonWhen weighing, the scale body shakes, the data is unstable, or the instrument displays error codes such as "Err".
-
reason:
- Loose or worn limit bolts result in excessive clearance between the scale body and the foundation.
- After long-term use, the limit block has aged and deformed.
-
Solution:
- Adjust the limit bolt to maintain a gap of 2-3mm between the scale body and the foundation.
- Replace the limit block: Use wear-resistant materials (such as nylon) for the limit block and regularly inspect and replace it.
2、 Sensor malfunction
1. Sensor damage
-
phenomenonData deviation during weighing (such as displaying non-zero values when unloaded), poor repeatability, or instrument display of "OL" (overload) alarm.
-
reason:
- Sensor overload damage caused by vehicle impact, overload, or unbalanced load.
- Poor sealing of the sensor, water ingress or moisture.
- The sensor wiring is loose or short circuited.
-
Solution:
- Replace sensor: Select a sensor that matches the prototype number (such as bridge or column) and recalibrate it.
- Check wiring: Use a multimeter to detect the sensor output signal and confirm that the wiring is not loose or short circuited.
- Waterproof treatment: Seal the sensor junction box to prevent water ingress.
2. Sensor signal interference
-
phenomenonThe weighing data fluctuates greatly or the instrument display is unstable.
-
reason:
- There is a strong electromagnetic field nearby (such as frequency converters, high-voltage lines).
- The sensor cable and power cable are laid in parallel, generating induced current.
-
Solution:
- Shielding interference: Lay the sensor cable through a metal tube or use shielded cables.
- Stay away from interference sources: Adjust the position of the weighing scale to avoid getting close to strong electromagnetic equipment.
- Grounding treatment: Ensure that sensors, instruments, and weighing scales are well grounded.
3、 Instrument display malfunction
1. No display or black screen on the instrument panel
-
phenomenonAfter power on, the instrument panel shows no response or the screen goes black.
-
reason:
- Power failure (such as blown fuses or broken power lines).
- Damage to the internal circuit board of the instrument (such as lightning strikes or unstable voltage).
- The backlight of the display screen is damaged.
-
Solution:
- Check the power supply: Use a multimeter to check if the power supply voltage is normal, replace the fuse or power cord.
- Repair instrument: Contact the manufacturer to replace the circuit board or display screen.
- Install voltage regulator: Install UPS or stabilized power supply in areas with unstable voltage.
2. Inaccurate weighing data
-
phenomenonThe deviation between the weighing value and the actual value is large, or the repeatability is poor.
-
reason:
- Instrument parameter settings are incorrect (such as mismatched range and division values).
- Abnormal sensor signal (such as a damaged sensor or inconsistent signal).
- Instrument calibration failure (such as failure to calibrate regularly or incorrect calibration methods).
-
Solution:
- Recalibration: Follow the instructions to perform angle and range calibration.
- Check sensors: Use standard weights to test the sensor output signals one by one to confirm consistency.
- Restore parameters: Restore instrument parameters to factory settings, reset range and division values.
4、 Electrical connection failure
1. Loose or disconnected wiring
-
phenomenonSometimes there is no data during weighing, or the instrument displays error codes such as "Err".
-
reason:
- Loose or oxidized wiring inside the sensor junction box.
- The cable between the instrument and the sensor is open or short circuited.
- Corrosion or damage to the wiring terminals.
-
Solution:
- Check wiring: Open the junction box and tighten all wiring terminals with a screwdriver.
- Testing cables: Use a multimeter to check for cable continuity and replace damaged cables.
- Anti corrosion treatment: Apply anti rust oil to the wiring terminals to prevent oxidation.
2. Lightning protection grounding failure
-
phenomenonAfter lightning strike, the weighing scale cannot function properly or the instrument is damaged.
-
reason:
- The lightning protection grounding device is not installed or the grounding resistance is too high.
- The grounding wire is broken or poorly connected.
-
Solution:
- Install lightning protection device: Install lightning protection module (such as surge protector) at the power inlet.
- Check grounding: Use a grounding resistance tester to measure the grounding resistance and ensure it is ≤ 4 Ω.
- Repair grounding wire: Replace the broken grounding wire to ensure a secure connection.
5、 Environmental interference fault
1. Temperature/humidity impact
-
phenomenonSlow instrument startup or data drift in low-temperature environments, and sensor signal attenuation in high-temperature environments.
-
reason:
- The internal components of the instrument are sensitive to temperature (such as changes in capacitance and resistance values).
- Poor sealing of the sensor and humidity caused a short circuit in the internal circuit.
-
Solution:
- Temperature control measures: Install a heater (low temperature environment) or a cooling fan (high temperature environment) inside the instrument box.
- Moisture proof treatment: Fill the sensor junction box with moisture-proof agent or select waterproof sensors.
2. Vibration/shock interference
-
phenomenonThe weighing data fluctuates greatly while the vehicle is in motion, or the instrument display is unstable.
-
reason:
- The foundation of the weighing scale is not isolated from vibration (such as being installed directly on a hard ground).
- Frequent starting/braking of the vehicle generates impact.
-
Solution:
- Shock absorption treatment: Install shock absorbers (such as rubber pads) between the foundation of the weighing scale and the ground.
- Speed limit: Set speed limit signs and require vehicles to drive at low speeds (≤ 5km/h).
6、 Daily maintenance suggestions
-
periodic calibrationConduct a comprehensive calibration every 6 months to ensure weighing accuracy.
-
Cleaning and maintenanceClean the surface debris of the scale body every week to prevent foreign objects from getting stuck in the sensor.
-
Check the wiringCheck the junction box and cable connections monthly, and tighten loose terminals.
-
Lightning protection testingInspect lightning protection grounding devices annually to ensure that the grounding resistance is qualified.
-
backup dataRegularly backup instrument parameters and weighing records to prevent data loss.