Date: 2016-09-12Read: 2

YGG YGGB Silicone Rubber Cable

YGG YGGB silicone rubber insulated (flame-retardant) soft power cable complies with the technical specifications of the Quality Supervision Center TICW/04-2009: suitable for high temperature range and harsh environment with rated voltage of 0.6/1kV and below, as an electrical equipment power transmission line. It has excellent characteristics such as high temperature resistance, flame retardancy, radiation resistance, aging resistance, ozone resistance, waterproofing, and has good cold resistance and weather resistance.

1、 Production execution standards(Executive standard):TICW/04-2009

2、 Usage characteristics

1Rated voltageUO/U:600/1000V.

1: Rated voltage UO/U:600/1000V

2Allowable working temperature range for cables-60℃~+180℃。

2 : W o r k in g te m p e r at ure all o we d b y c a b l e is-60℃~+180.

3During a short circuit(The duration should not exceed5S)The maximum temperature of the cable conductor shall not exceed250℃。

3: Max temperature of cable conductor is no more than 250during short circuit(The longest lasting time isno more than 5s.)

4The temperature for cable laying should not be lower than-20℃。

4.Temperature for installing is no less than -20.

5The bending radius of the cable is as follows: the bending radius of a single core cable shall not be less than the outer diameter of the cable15D;(D-Cable outer diameter);

The bending radius of a three core cable shall not be less than the outer diameter of the cable12D.

5.Bending radius of cable as follows:It is no less than 15 times that of cable outer diameter for cable with single coreIt is no less than 12 times that of cable outer diameter for cable with three cores

3、 Cable model name(Type and Description)

1.YGGP

Silicone rubber insulation, silicone rubber sheath, copper wire braided shielding(flame retardant)Power flexible cable

(flame retardant)power soft cable with silicon rubber insulation and sheath, copper wire braided shielding

2. YGV

Silicone rubber insulated polyvinyl chloride sheath(flame retardant)Power flexible cable

(flame retardant)power soft cable with silicon rubber insulation and butadiene PVC sheath

3. YGG22

4、 Technical parameters

Technical parameter

1Finished cable conductor20DC resistance at ℃:Should meetGB/ T3956The standard requires that the DC resistance of the conductive core of the finished cable be converted to the length of the cable1mThe nominal cross-section is1mm2And the temperature is20At ℃, the copper core wire should not exceed0.0184Oh.

2Insulation resistance of finished cable insulation core: The insulation resistance of finished cable insulation core, converted to cable length, is1kmAnd the temperature is20At ℃, the conductive wire core

Section in50mm2The following should not be less than50MΩ,70~185mm2Should it beless than35MOh.

3Finished cables should withstand power frequency AC test voltage3000VThe5minVoltage test, insulation without breakdown.

Technical parameter

  1. DC resistance of finished cable conductor at 20shall meet the requirement of GB/T3956 standard. Con-ductive core DC resistance of finished cable is no more than 0.0184Ωfor cable with cross section 1mm2 under the condition that cable length is 1m and temperature is 20.

2.Insulated resistance of finished cable insulatedconductor will be no less than 50MΩfor cable with con-ductive core cross section 50mm2 or lower and 35 MΩfor cable with conductive core cross section 70 ~185mm2 under the condition that cable length is 1km and tempera-ture is 20.

3: Finished c able shall bear A . C voltage test of 350 0V under power frequency for 5 minutes without puncture of insulation.

YGG YGGB silicone rubber insulated (flame-retardant) flexible power cable complies with the technical specifications of the Quality Supervision Center TICW/04-2009

5、 Specification Range Specification

Cable specifications use the number of conductor cores multiplied by the nominal cross-sectional area of the conductormm2Represented as shown in the table2

core number * nominal cross section areastandsfor cable specification. Please see the following table 2)

model

Number of cores

Nominal cross-sectionmm2

Type

Core number

Nominal cross section area

(ZR)-HGG

(ZR)-HGGP

Single core:1.5500

(ZR)-HGGP2

12345

Multi core:1.5240

(ZR)-HGVF

3+23+1

1.5500 for single core

(ZR)-HGVFP

1.5240 for multi-core

(ZR)-HGVF22

(ZR)-HGVFP2

waterproof cable wire and cable Compensation wire and cable thermocouple High temperature resistant silicone rubber cable

MC MCP coal mining machine flexible cable MY MYP coal mine mobile flexible cable YGGB YFFB high-temperature resistant flat cable

WDZAN-YJY WDZA-YJY low smoke halogen-free flame-retardant, fire-resistant and environmentally friendly power cable Cross linked polyethylene power cable

6、 Delivery length

Allow delivery according to the agreed length between both parties; The length measurement error shall not exceed ±0.5%.